Data Center Technology: Physical Infrastructure

Size: px
Start display at page:

Download "Data Center Technology: Physical Infrastructure"

Transcription

1 Data Center Technology: Physical Infrastructure IT Trends Affecting New Technologies and Energy Efficiency Imperatives in the Data Center Hisham Elzahhar Regional Enterprise & System Manager, Schneider Electric IT business EMEA, Dubai

2 Keystrokes Kilowatts Heat OUT Electricity IN 2

3 US Electrical Energy Sources 2006 Other Renew ables Hydro-Electric 2% 7% Nuclear 19% Natural Gas 20% Petroleum 2% CoalCoal 50% Coal Petroleum Natural Gas Nuclear Hydro-Electric Other Renewables Source US EIA 3

4 Prime Electrical Source 4

5 WHICH infrastructure? BUILDING infrastructure Building systems HVAC Electrical system Fire suppression Lighting Security BMS DATA CENTER infrastructure Power Cooling Racks Management Lighting Fire suppression Physical security IT infrastructure IT assets Servers, storage hypervisors,, NMS NETWORK infrastructure Switches, cabling, routers 5

6 WHICH infrastructure? Focus of this discussion BUILDING infrastructure Building systems HVAC Electrical system Fire suppression Lighting Security BMS DATA CENTER infrastructure Power Cooling Racks Management Lighting Fire suppression Physical security IT infrastructure IT assets Servers, storage hypervisors,, NMS NETWORK infrastructure Switches, cabling, routers 6

7 Data center planning and operation is under increasing pressures Increasing availability Rapid changes in expectations IT technology Uncertain long-term plans for Energy and service capacity or density cost control pressure High density blade server power/heat Dynamic power variation Regulatory requirements Server consolidation In response, will need to change the way the world designs, installs, operates, manages, and maintains data centers 7

8 The increasing power density of data centers Management challenge: HIGH DENSITY Power density of IT devices is leveling off but power density of data centers data centers continues to increase due to packing of high-density devices into smaller floor footprint KW per rack continues to increase, raising the need for management to keep things under control 8

9 High density is stressing Management challenge: HIGH DENSITY power and cooling systems IT is getting boxed-in by limitations of power and cooling infrastructure High density increases the risk of unpredictable cooling Capacity is tight in some places, unused and unusable ( stranded ) in others High density requires informed and efficient allocation of your expensive power/cooling resources High density increases the need to know where new devices can be squeezed in to available capacities 9

10 The Newest Challenge: EFFICIENCY Efficiency goal: Provide power and cooling in the amount needed, when needed, and where needed but no more than what is required for redundancy and safety margins But we can t manage what we can t measure 10

11 Datacenter Efficiency - DCiE Data center Power to data center Power path to IT POWER system Power to IT IT equipment Power to Secondary Support COOLING system Physical infrastructure* *To simplify the analysis, subsystems consuming a small amount of power are not included in this discussion: Cabling Physical security Switches Generator Lights Switchgear White paper 113 = Data Center infrastructure Efficiency Power to IT Power to data center ( )% 11

12 Datacenter Efficiency Data Center Physical Infrastructure IT COOLING COOLING system system POWER POWER system system 12

13 Power Chain Losses 4,930 barrels 47 tons SO2 16 tons N2O 6,539 tons CO2 Per mw/yr 1mW 47% 45 10kW 13

14 Inefficiencies Create Consumption Computing inefficiencies > More servers Server inefficiencies > More power and cooling Power and cooling inefficiencies > More power consumption Inefficiencies drive both power consumption and material consumption 14

15 Primary drivers of inefficiency Oversizing of power and cooling equipment Pushing cooling systems to cool densities higher than they were designed for Ineffective room layout Ineffective airflow patterns Redundancy (for availability) Inefficient power and cooling equipment Inefficient operating settings of cooling equipment Clogged air or water filters Disabled or malfunctioning cooling economizer modes Raised floor clogged with wires 15

16 Efficiency: key reference points More than 50% of the power going into a typical data center goes to the power and cooling systems NOT to the IT loads The typical 1MW (IT load) data center is continuously wasting about 400kW or 2,000 tons of coal per year due to poor design (DCiE = 50%, instead of best-practice 70%) Every kw saved in a data center saves about $1,000 per year Every kw saved in a data center reduces carbon dioxide emissions by 5 tons per year Every kw saved in a data center has a carbon reduction equivalent to eliminating about 1 car from the road. A 1% improvement in data center infrastructure efficiency (DCiE) corresponds to approximately 2% reduction in electrical bills References: APC White Paper 66 16

17 Power tools for The Efficient Enterprise 17

18 Power tools The Four Cs 1 2 omponents MODULAR and SCALABLE, with best-in-class EFFICIENCY lose-coupled cooling Placement of cooling units near the heat source 3 ontainment Thermal containment of airflow in high-density zones 4 apacity management Instrumented intelligence to optimize use of power and cooling capacity 18

19 1 omponents with the right stuff Best-in-class component EFFICIENCY Efficient Agile MODULAR SCALABLE component design Scalable External modularity Internal modularity 19

20 Problem: Underloading Low loading = low efficiency In a traditional data center, over half the power consumption of the power/cooling infrastructure is fixed and does not go down when IT load goes down Efficiency degrades as IT load declines Underloading is a primary contributor to inefficiency Data center Efficiency E ffic ie n c y 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% Efficiency degrades at low loads Typical load range 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % IT Load IT load 20

21 Solution: Right-sizing Efficiency gain through modular scalable buildout avoids oversizing / underloading Data center Efficiency Efficiency 100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% Power and cooling installation method 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % IT load Load 21

22 Modular scalable design Reduce power consumption up to 30% by right right-sizing sizing power and cooling infrastructure Avoid underloading run more efficiently Pay only for what you need, when you need it P = Power C = Cooling R = Racks 22

23 500kW of scalable, high-efficiency power protection 100kW 125kW 150kW 175kW 200kW 225kW 250kW 275kW 300kW 325kW 350kW 375kW 400kW 425kW 450kW 500kW 475kW 23

24 lose-coupled cooling Reduce power consumption up to 20% with InRow architecture Closely couples cooling with heat load, preventing exhaust air recirculation Less fan power than traditional raised-floor system Varying equipment temperatures are constantly held to set point conditions Lowers operating cost by monitoring inlet temperatures to modulate cooling capacity based on the cooling demand Fan speed adjusts to follow changing IT heat load 24

25 Close-coupled cooling InRow air conditioner Heat captured and rejected to chilled water Cold air is supplied to the cold aisle Hot-aisle air enters from rear, preventing mixing Hot aisle Cold aisle Can operate on hard floor or raised floor 25

26 Efficiency comparison 100% 90% Cooling Efficiency Cooling efficiency 80% 70% 60% 50% 40% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% IT load % IT Load Cooling efficiency = useful cooling power / (power consumed + useful cooling power) 26

27 ontainment Eliminate expensive temperature cross-contamination contamination with thermal containment options Simplifies analysis and understanding of the thermal environment Hot Aisle Containment (HAC) Increases predictability of the cooling system Increases cooling EFFICIENCY and cooling CAPACITY by returning warmest possible air to cooling units Ensures proper air distribution by separating supply and return air paths Rack Air Containment (RAC) 27

28 Rack Air Containment Rear Rear Containment Rear containment prevents hot exhaust air from escaping InRow cooling unit InRow cooling unit All exhaust air is returned to InRow cooling unit Optional front containment directs cool air to front of servers Allows up to 60 kw per rack (30 kw with N+1 redundancy) NetShelter SX rack Front Containment Front Top Down View 28

29 Hot aisle containment vs traditional room cooling Inherently higher power density capability than room designs Fan power is reduced by 50% Needless dehumidification / re-humidification is eliminated Need for high-bay areas and raised floors is reduced or eliminated (particularly for small installations) Cooling capacity can follow IT loads that move due to virtualization and server power management C o o l i n g E f f i c i e n c y 100% 90% 80% 70% 60% 50% 40% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % IT Load Cooling efficiency = useful cooling power / (power consumed + useful cooling power) 29

30 Hot Aisle Containment areas can be added as needed 30

31 apacity Management Increase IT staff efficiency with predictable Capacity Management Identify over- and under-utilized areas of your data center Minimize waste and human error via predictable software monitoring, sensing, and environmental control Quickly adapt to change with real-time data on what to power and where to cool 31

32 Capacity Manager Physical equipment provisioning Quickly locate the optimum spot for that next server based on space, cooling, and power needs Rack elevations Easy-to-use front view for accurate and detailed representation of equipment layout Airflow analysis Locate new devices without overheating new or existing equipment by simulating changes in; supply temperature, airflow and number of cooling units Available capacity Understand available capacity by calculating actual space, power and cooling consumption against data center architecture constraints Capacity grouping Specify architecture capabilities to; match IT equipment with availability needs ad avoid stranded space, power and cooling capacity Design analysis Model the effects of and compare alternative layouts through detailed design analysis 32

33 Capacity and energy management Poor utilization of capacity is a primary cause of inefficiency Software can identify available capacity (even by rack) and help prevent creation of stranded capacity Side effect is you can fit more IT equipment in the power and cooling envelope of the data center Energy management can identify efficiency improvement opportunities Infrastructure Central Software With Capacity Manager 33

34 Power consumptions compared to the IT load IT Load Aux Devices Lights Humidifier Chiller Pumps Heat Rejection CRAC Distribution Wiring Switchgear Generator Improving efficiency means working to reduce power consumption (increase efficiency) for each of these device categories PDU UPS Reference: APC White Paper 114 0% 20% 40% 60% 80% 100% 120% Power Power consumption Consumption as as % of % the of IT IT Load load 0.0% 20.0% 40.0% 60.0% 80.0% 100.0% 120.0% Data for a typical tier 4 data center operating at 30% of rated load 34

35 Drivers of infrastructure efficiency gains (Baseline: Average of existing installed base) IMPROVEMENT Device Gain DCiE Gain $$ saved over 15 years in a 1MW data center** Move from room cooling to dynamic row/rack cooling 70% 8% $5,900,000 Cooling economizers 38% 4% $2,500,000 Right-sizing through modular power and cooling equipment 4% 4% $2,400,000 Higher UPS efficiency 8% 4% $1,900, /240 V transformerless power distribution (NAM)* Dynamic control of cooling plant (VFD fans, pumps, chillers) 4% 2.5% $1,500,000 25% 2.5% $1,200,000 TOTAL to get industry from 47% to 72% DCiE 25% 25% $14,700,000 *No benefit outside of NAM; Transformer based PDUs typically in NAM only **$$ values based on $.15 per kwh electric cost, starting DCiE of 47%, ave density 8KW/rack 35

36 Power Chain Losses Could Be 4,930 barrels 6,539 tons CO2 47 tons SO2 16 tons N2O Per mw/yr 1,971 barrels 2,615 tons CO2 19 tons SO2 6 tons N2O 1mW 400kW 70% 36

37 Visit us Hall 4, booth 4405 (next to the BP Carbon Theater) Tour the booth and be entered into our daily lottery The lucky winner to receive a brand new Amazon Kindle e-reading device right away! 37

38 Questions? 38

The Efficient Enterprise. Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric

The Efficient Enterprise. Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric Ee The Efficient Enterprise Juan Carlos Londoño Data Center Projects Engineer APC by Schneider Electric Keystrokes Kilowatts Heat OUT Electricity IN Need for bandwidth exploding Going hyperbolic! 30,000

More information

An Improved Architecture for High-Efficiency, High-Density Data Centers

An Improved Architecture for High-Efficiency, High-Density Data Centers An Improved Architecture for High-Efficiency, High-Density Data Centers By Neil Rasmussen White Paper #126 Executive Summary Data center power and cooling infrastructure worldwide wastes more than 60,000,000

More information

Re Engineering to a "Green" Data Center, with Measurable ROI

Re Engineering to a Green Data Center, with Measurable ROI Re Engineering to a "Green" Data Center, with Measurable ROI Alan Mamane CEO and Founder Agenda Data Center Energy Trends Benchmarking Efficiency Systematic Approach to Improve Energy Efficiency Best Practices

More information

APC by Schneider Electric

APC by Schneider Electric APC by Schneider Electric Energy Efficiency - The Green Power Solution James Taylor Business Development manager, UK APC by Schneider Electric The Efficient Enterprise Components Close Coupled Cooling

More information

Energy Efficiency @ Datacenter. Schneider Electric

Energy Efficiency @ Datacenter. Schneider Electric Green Data Centers Energy Efficiency @ Datacenter Solutions of the past are simply not sufficient for the future Future F t of human prosperity depends d on : How successfully we tackle the two central

More information

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009 Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009 Agenda Overview - Network Critical Physical Infrastructure Cooling issues in the Server Room

More information

Guide for Reducing Data Center Physical Infrastructure Energy Consumption in Federal Data Centers

Guide for Reducing Data Center Physical Infrastructure Energy Consumption in Federal Data Centers Guide for Reducing Data Center Physical Infrastructure Energy Consumption in Federal Data Centers October 2010/White Paper 250 by Dennis Bouley, Senior Research Analyst Data Center Science Center and Ellen

More information

Management Tools for Data Center Physical Infrastructure

Management Tools for Data Center Physical Infrastructure Management Tools for Data Center Physical Infrastructure Jack Hack Data Center Solutions BeLux Software Consultant Benelux APC by Schneider Electric X-ICT Xperience 2010 15 April Management Tools for Data

More information

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTERS 2009 IT Emissions = Aviation Industry Emissions Nations Largest Commercial Consumers of Electric Power Greenpeace estimates

More information

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory

More information

How Row-based Data Center Cooling Works

How Row-based Data Center Cooling Works How Row-based Data Center Cooling Works White Paper 208 Revision 0 by Paul Lin and Victor Avelar Executive summary Row-based data center cooling is normally regarded as a cold air supply architecture that

More information

Power and Cooling Capacity Management for Data Centers

Power and Cooling Capacity Management for Data Centers Power and Cooling Capacity for Data Centers By Neil Rasmussen White Paper #150 Executive Summary High density IT equipment stresses the power density capability of modern data centers. Installation and

More information

> Executive summary. Virtualization: Optimized Power and Cooling to Maximize Benefits. White Paper 118 Revision 2. Contents.

> Executive summary. Virtualization: Optimized Power and Cooling to Maximize Benefits. White Paper 118 Revision 2. Contents. Virtualization: Optimized Power and Cooling to Maximize Benefits White Paper 118 Revision 2 by Suzanne Niles Click on a section to jump to it > Executive summary Data centers are routinely and unknowingly

More information

Electrical Efficiency Modeling for Data Centers

Electrical Efficiency Modeling for Data Centers Electrical Efficiency Modeling for Data Centers By Neil Rasmussen White Paper #113 Revision 1 Executive Summary Conventional models for estimating electrical efficiency of data centers are grossly inaccurate

More information

APC APPLICATION NOTE #112

APC APPLICATION NOTE #112 #112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.

More information

Rack Hygiene. Data Center White Paper. Executive Summary

Rack Hygiene. Data Center White Paper. Executive Summary Data Center White Paper Rack Hygiene April 14, 2011 Ed Eacueo Data Center Manager Executive Summary This paper describes the concept of Rack Hygiene, which positions the rack as an airflow management device,

More information

APC APPLICATION NOTE #92

APC APPLICATION NOTE #92 #92 Best Practices for Designing Data Centers with the InfraStruXure InRow RC By John Niemann Abstract The InfraStruXure InRow RC is designed to provide cooling at the row and rack level of a data center

More information

The Pros and Cons of Modular Systems

The Pros and Cons of Modular Systems The Pros and Cons of Modular Systems Kevin Brown, Vice President Global Data Center Offer Schneider Electric Schneider Electric 1 Foundational BUSINESS OVERVIEW Rev 2 Desired characteristics of pre-fabricated

More information

abstract about the GREEn GRiD

abstract about the GREEn GRiD Guidelines for Energy-Efficient Datacenters february 16, 2007 white paper 1 Abstract In this paper, The Green Grid provides a framework for improving the energy efficiency of both new and existing datacenters.

More information

National Grid Your Partner in Energy Solutions

National Grid Your Partner in Energy Solutions National Grid Your Partner in Energy Solutions National Grid Webinar: Enhancing Reliability, Capacity and Capital Expenditure through Data Center Efficiency April 8, 2014 Presented by: Fran Boucher National

More information

Building a Real Data Center During the Great Recession

Building a Real Data Center During the Great Recession Building a Real Data Center During the Great Recession Steven Carlini Sr Director, Data Center Global Solution Offer Management APC by Schneider Electric Schneider Electric at a glance global, innovative

More information

DATA CENTER ASSESSMENT SERVICES

DATA CENTER ASSESSMENT SERVICES DATA CENTER ASSESSMENT SERVICES ig2 Group Inc. is a Data Center Science Company which provides solutions that can help organizations automatically optimize their Data Center performance, from assets to

More information

Airflow Simulation Solves Data Centre Cooling Problem

Airflow Simulation Solves Data Centre Cooling Problem Airflow Simulation Solves Data Centre Cooling Problem The owner s initial design for a data centre in China utilized 40 equipment racks filled with blade servers spread out in three rows along the length

More information

Power and Cooling for Ultra-High Density Racks and Blade Servers

Power and Cooling for Ultra-High Density Racks and Blade Servers Power and Cooling for Ultra-High Density Racks and Blade Servers White Paper #46 Introduction The Problem Average rack in a typical data center is under 2 kw Dense deployment of blade servers (10-20 kw

More information

Imperial College 3 March 2009 Green Data Centers: An Overview

Imperial College 3 March 2009 Green Data Centers: An Overview Imperial College 3 March 2009 Green Data Centers: An Overview Updated: 26 Feb 09 LBNL s Data Center findings Benchmarking Efforts Energy Reduction Approaches Green Data Centers: An Overview 2 Scenarios

More information

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED. Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED. Presentation Goals & Outline Power Density Where we have been- where we are now - where we are going Limitations of Air Cooling

More information

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

AIR-SITE GROUP. White Paper. Green Equipment Room Practices AIR-SITE GROUP White Paper Green Equipment Room Practices www.air-site.com Common practices to build a green equipment room 1 Introduction Air-Site (www.air-site.com) is a leading international provider

More information

How To Power And Cool A Data Center

How To Power And Cool A Data Center Architecting the Green Data Center Viktor Hagen Field Business Development Data Center & High Performance Computing 1 Where we are Today Environmental sustainability is a major global trend for the 21st

More information

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Dealing with Thermal Issues in Data Center Universal Aisle Containment Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe Daniele.Tordin@Panduit.com AGENDA Business Drivers Challenges

More information

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert

Data Center Consolidation Trends & Solutions. Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert Data Center Consolidation Trends & Solutions Bob Miller Vice President, Global Solutions Sales Emerson Network Power / Liebert Agenda Traditional Data Centers Drivers of a Changing Environment Alternate

More information

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably Data Center 2020: Delivering high density in the Data Center; efficiently and reliably March 2011 Powered by Data Center 2020: Delivering high density in the Data Center; efficiently and reliably Review:

More information

Electrical Efficiency Modeling of Data Centers

Electrical Efficiency Modeling of Data Centers Electrical Efficiency Modeling of Data Centers By Neil Rasmussen White Paper 113 Executive Summary The conventional models used to estimate electrical efficiency of data centers are grossly inaccurate

More information

Cisco Data Center Facilities Assessment Service

Cisco Data Center Facilities Assessment Service Cisco Data Center Facilities Assessment Service Increase the availability, capacity, and life of your data center facility. Service Overview Data centers must respond to changing business needs, environmental

More information

White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010

White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010 White Paper Data Center Containment Cooling Strategies WHITE PAPER EC9001 Geist Updated August 2010 Abstract Deployment of high density IT equipment into data center infrastructure is now a common occurrence

More information

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power and cooling savings through the use of Intel

More information

ICT and the Green Data Centre

ICT and the Green Data Centre ICT and the Green Data Centre Scott McConnell Sales Manager c/o Tanya Duncan MD Interxion Ireland Green Data Centres Our Responsibility Data centre greenhouse gas emissions are projected to quadruple by

More information

Impact of Virtualization on Data Center Physical Infrastructure White Paper #27. Tom Brey, IBM Operations Work Group

Impact of Virtualization on Data Center Physical Infrastructure White Paper #27. Tom Brey, IBM Operations Work Group Impact of Virtualization on Data Center Physical Infrastructure White Paper #27 Tom Brey, IBM perations Work Group 1 Virtualization Two Steps WP #19 USING VIRTUALIZATIN T IMPRVE DATA CENTER EFFICIENCY

More information

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency

More information

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM) Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM) Salim Janbeh Physical Infrastructure Consultant uae-sj@panduit.com PANDUIT You Can t Manage What You Don t Measure:

More information

The Advantages of Row and Rack- Oriented Cooling Architectures for Data Centers

The Advantages of Row and Rack- Oriented Cooling Architectures for Data Centers The Advantages of Row and Rack- Oriented Cooling Architectures for Data Centers By Kevin Dunlap Neil Rasmussen White Paper #130 Executive Summary Room cooling is an ineffective approach for next-generation

More information

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY

AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY AEGIS DATA CENTER SERVICES POWER AND COOLING ANALYSIS SERVICE SUMMARY The Aegis Services Power and Assessment Service provides an assessment and analysis of your data center facility and critical physical

More information

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Energy Efficiency Best Practice Guide Data Centre and IT Facilities 2 Energy Efficiency Best Practice Guide Data Centre and IT Facilities Best Practice Guide Pumping Systems Contents Medium-sized data centres energy efficiency 3 1 Introduction 4 2 The business benefits

More information

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms Agenda Review of cooling challenge and strategies Solutions to deal with wiring closet cooling Opportunity and value Power

More information

Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services

Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services Data Center & IT Infrastructure Optimization Trends & Best Practices Mickey Iqbal - IBM Distinguished Engineer IBM Global Technology Services IT Organizations are Challenged by a Set of Operational Issues

More information

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015 S c h n e i d e r E l e c t r i c BUSINESS IMPACT Datacenter means business - create the bridge between IT en Facilities. Jack Hack Enterprise System Engineer 19 November 2015 1 Your ability to compete

More information

Implementing Energy Efficient Data Centers

Implementing Energy Efficient Data Centers Implementing Energy Efficient Data Centers By Neil Rasmussen White Paper #114 Executive Summary Electricity usage costs have become an increasing fraction of the total cost of ownership (TCO) for data

More information

Power and Cooling Guidelines for Deploying IT in Colocation Data Centers

Power and Cooling Guidelines for Deploying IT in Colocation Data Centers Power and Cooling Guidelines for Deploying IT in Colocation Data Centers White Paper 173 Revision 0 by Paul Lin and Victor Avelar Executive summary Some prospective colocation data center tenants view

More information

Green Data Centre Design

Green Data Centre Design Green Data Centre Design A Holistic Approach Stantec Consulting Ltd. Aleks Milojkovic, P.Eng., RCDD, LEED AP Tommy Chiu, EIT, RCDD, LEED AP STANDARDS ENERGY EQUIPMENT MATERIALS EXAMPLES CONCLUSION STANDARDS

More information

Benefits of. Air Flow Management. Data Center

Benefits of. Air Flow Management. Data Center Benefits of Passive Air Flow Management in the Data Center Learning Objectives At the end of this program, participants will be able to: Readily identify if opportunities i where networking equipment

More information

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense CarbonDecisions The green data centre Why becoming a green data centre makes good business sense Contents What is a green data centre? Why being a green data centre makes good business sense 5 steps to

More information

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009 Optimum Climate Control For Datacenter - Case Study T. Prabu March 17 th 2009 Agenda 2 About EDEC (Emerson) Facility Data Center Details Design Considerations & Challenges Layout Design CFD Analysis Of

More information

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions

How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Intel Intelligent Power Management Intel How High Temperature Data Centers & Intel Technologies save Energy, Money, Water and Greenhouse Gas Emissions Power savings through the use of Intel s intelligent

More information

Best Practice Guide for Data Centres - a UH Perspective Steve Bowes-Phipps, Data Centres Manager University of Hertfordshire

Best Practice Guide for Data Centres - a UH Perspective Steve Bowes-Phipps, Data Centres Manager University of Hertfordshire Best Practice Guide for Data Centres - a UH Perspective Steve Bowes-Phipps, Data Centres Manager University of Hertfordshire http://rare idc.herts.ac.uk Best Practice Guide for Data Centres RARE-IDC Overview

More information

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers Prepared for the U.S. Department of Energy s Federal Energy Management Program Prepared By Lawrence Berkeley National

More information

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc. High Density Data Centers Fraught with Peril Richard A. Greco, Principal EYP Mission Critical Facilities, Inc. Microprocessors Trends Reprinted with the permission of The Uptime Institute from a white

More information

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions Free Cooling in Data Centers John Speck, RCDD, DCDC JFC Solutions Why this topic Many data center projects or retrofits do not have a comprehensive analyses of systems power consumption completed in the

More information

Strategies for Deploying Blade Servers in Existing Data Centers

Strategies for Deploying Blade Servers in Existing Data Centers Strategies for Deploying Blade Servers in Existing Data Centers By Neil Rasmussen White Paper #125 Revision 1 Executive Summary When blade servers are densely packed, they can exceed the power and cooling

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

Introducing Computational Fluid Dynamics Virtual Facility 6SigmaDC

Introducing Computational Fluid Dynamics Virtual Facility 6SigmaDC IT Infrastructure Services Ltd Holborn Gate, 330 High Holborn, London, WC1V 7QT Telephone: +44 (0)20 7849 6848 Fax: +44 (0)20 7203 6701 Email: info@itisltd.co.uk www.itisltd.com Introducing Computational

More information

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings WHITE PAPER Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings By Lars Strong, P.E., Upsite Technologies, Inc. Kenneth G. Brill, Upsite Technologies, Inc. 505.798.0200

More information

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Overview of Green Energy Strategies and Techniques for Modern Data Centers Overview of Green Energy Strategies and Techniques for Modern Data Centers Introduction Data centers ensure the operation of critical business IT equipment including servers, networking and storage devices.

More information

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment

More information

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions

Data Centre Solutions... energy efficient by design. APC by Schneider Electric Elite Data Centre Partner. APC s leading Elite Data Centre Solutions Data Centre Solutions... energy efficient by design APC by Schneider Electric Elite Data Centre Partner APC s leading Elite Data Centre Solutions Partner providing customers with expert advice, integration

More information

Hot-Aisle vs. Cold-Aisle Containment for Data Centers

Hot-Aisle vs. Cold-Aisle Containment for Data Centers Hot-Aisle vs. Cold-Aisle Containment for Data Centers White Paper 135 Revision 1 by John Niemann, Kevin Brown, and Victor Avelar > Executive summary Both hot-air and cold-air containment can improve the

More information

BICSInews. plus. july/august 2012. + Industrial-grade Infrastructure. + I Say Bonding, You Say Grounding + Data Center Containment.

BICSInews. plus. july/august 2012. + Industrial-grade Infrastructure. + I Say Bonding, You Say Grounding + Data Center Containment. BICSInews m a g a z i n e july/august 2012 Volume 33, Number 4 plus + Industrial-grade Infrastructure and Equipment + I Say Bonding, You Say Grounding + Data Center Containment & design deployment The

More information

Specification of Modular Data Center Architecture

Specification of Modular Data Center Architecture Specification of Modular Data Center Architecture White Paper 160 Revision 1 by Neil Rasmussen > Executive summary There is a growing consensus that conventional legacy data center design will be superseded

More information

Managing Data Centre Heat Issues

Managing Data Centre Heat Issues Managing Data Centre Heat Issues Victor Banuelos Field Applications Engineer Chatsworth Products, Inc. 2010 Managing Data Centre Heat Issues Thermal trends in the data centre Hot Aisle / Cold Aisle design

More information

The Next Generation APC by Schneider Electric InfraStruxure

The Next Generation APC by Schneider Electric InfraStruxure The Next Generation APC by Schneider Electric InfraStruxure Data Centre physical infrastructure architecture Data Centres and Networks Introducing the Next Generation InfraStruxure The data centre architecture

More information

Legacy Data Centres Upgrading the cooling capabilities What are the options?

Legacy Data Centres Upgrading the cooling capabilities What are the options? Legacy Data Centres Upgrading the cooling capabilities What are the options? Presentation Structure What is a Legacy Data Centre? What is CRAC cooling? ASHRAE Standards Overview Available Cooling Systems

More information

The New Data Center Cooling Paradigm The Tiered Approach

The New Data Center Cooling Paradigm The Tiered Approach Product Footprint - Heat Density Trends The New Data Center Cooling Paradigm The Tiered Approach Lennart Ståhl Amdahl, Cisco, Compaq, Cray, Dell, EMC, HP, IBM, Intel, Lucent, Motorola, Nokia, Nortel, Sun,

More information

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie Mukesh Khattar, Energy Director, Oracle National Energy Efficiency Technology Summit, Sep. 26, 2012, Portland, OR Agenda

More information

Design Best Practices for Data Centers

Design Best Practices for Data Centers Tuesday, 22 September 2009 Design Best Practices for Data Centers Written by Mark Welte Tuesday, 22 September 2009 The data center industry is going through revolutionary changes, due to changing market

More information

Data Centre Testing and Commissioning

Data Centre Testing and Commissioning Data Centre Testing and Commissioning What is Testing and Commissioning? Commissioning provides a systematic and rigorous set of tests tailored to suit the specific design. It is a process designed to

More information

An Introduction to Cold Aisle Containment Systems in the Data Centre

An Introduction to Cold Aisle Containment Systems in the Data Centre An Introduction to Cold Aisle Containment Systems in the Data Centre White Paper October 2010 By Zac Potts MEng Mechanical Engineer Sudlows October 2010 An Introduction to Cold Aisle Containment Systems

More information

Elements of Energy Efficiency in Data Centre Cooling Architecture

Elements of Energy Efficiency in Data Centre Cooling Architecture Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total

More information

Data Center Equipment Power Trends

Data Center Equipment Power Trends Green field data center design 11 Jan 2010 by Shlomo Novotny Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp. explores water cooling for maximum efficiency - Part 1 Overview Data

More information

Improving Data Center Energy Efficiency Through Environmental Optimization

Improving Data Center Energy Efficiency Through Environmental Optimization Improving Data Center Energy Efficiency Through Environmental Optimization How Fine-Tuning Humidity, Airflows, and Temperature Dramatically Cuts Cooling Costs William Seeber Stephen Seeber Mid Atlantic

More information

Cheat Sheets to Data Center Infrastructure Management

Cheat Sheets to Data Center Infrastructure Management ^ Business-wise, Future-drivenTM Cheat Sheets to Data Center Infrastructure Management The Brands You Trust. Table of Contents Introduction...3 How DCIM helps operations...4 How DCIM helps planning...5

More information

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Reference Guide: SmartDesign Approach: Common Data Center Challenges: Smart Solutions Reference Guide Solutions For Business-Critical Continuity 1100kW Tier 3 With High Density Design Intelligent, Integrated Infrastructure for the Data Center Reference Guide: 1100kW Tier

More information

Great Lakes Data Room Case Study

Great Lakes Data Room Case Study Great Lakes Data Room Case Study WeRackYourWorld.com Problem: During a warm summer period in 2008, Great Lakes experienced a network outage due to a switch failure in the network enclosure. After an equipment

More information

How To Test A Theory Of Power Supply

How To Test A Theory Of Power Supply A CASE STUDY ON: THE EFFECTS OF HIGHER OPERATING TEMPERATURES ON DATA CENTER EFFICIENCY Victor Garcia Director of Facilities Brocade October 24, 2012 Jeff Stein, PE Principal Taylor Engineering 2010 Brocade

More information

Improves Planning and Cuts Operational Costs White Paper 107

Improves Planning and Cuts Operational Costs White Paper 107 Infrastructure Management Software Improves Planning and Cuts Operational Costs White Paper 107 Revision 0 by Torben Karup Nielsen and Dennis Bouley > Executive summary Business executives are challenging

More information

Cooling Audit for Identifying Potential Cooling Problems in Data Centers

Cooling Audit for Identifying Potential Cooling Problems in Data Centers Cooling Audit for Identifying Potential Cooling Problems in Data Centers By Kevin Dunlap White Paper #40 Revision 2 Executive Summary The compaction of information technology equipment and simultaneous

More information

VISIT 2010 Fujitsu Forum Europe 0

VISIT 2010 Fujitsu Forum Europe 0 VISIT 2010 Fujitsu Forum Europe 0 Virtualization & Automation Room 13a Shaping tomorrow with you. Green Data Center Services Martin Provoost Director, Data Centers and Networks, Fujitsu UK & Ireland 14:00

More information

Introducing UNSW s R1 Data Centre

Introducing UNSW s R1 Data Centre Introducing UNSW s R1 Data Centre R1-DC Our New High Density Data Centre Right here Right now - Welcome to our newest UNSW Data Centre R1-DC R1 Location on UNSW Randwick campus. Keeping it in the family

More information

Creating Data Center Efficiencies Using Closed-Loop Design Brent Goren, Data Center Consultant

Creating Data Center Efficiencies Using Closed-Loop Design Brent Goren, Data Center Consultant RESEARCH UNDERWRITER WHITE PAPER LEAN, CLEAN & GREEN Wright Line Creating Data Center Efficiencies Using Closed-Loop Design Brent Goren, Data Center Consultant Currently 60 percent of the cool air that

More information

Statement Of Work. Data Center Power and Cooling Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary

Statement Of Work. Data Center Power and Cooling Assessment. Service. Professional Services. Table of Contents. 1.0 Executive Summary Statement Of Work Professional Services Data Center Power and Cooling Assessment Data Center Power and Cooling Assessment Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features

More information

Data Centers That Deliver Better Results. Bring Your Building Together

Data Centers That Deliver Better Results. Bring Your Building Together Data Centers That Deliver Better Results Bring Your Building Together 1 Meeting the high demands of your data center Meeting the increasing heat loads associated with growing computational needs requires

More information

GREEN DATA CENTER DESIGN

GREEN DATA CENTER DESIGN Jeffrey Menig Global Facilities Facility Engineering The application of multiple available technologies resulting in improved energy optimization without significantly increasing capital investment. A

More information

Data Center Facility Basics

Data Center Facility Basics Data Center Facility Basics Ofer Lior, Spring 2015 Challenges in Modern Data Centers Management, Spring 2015 1 Information provided in these slides is for educational purposes only Challenges in Modern

More information

Interested in conducting your own webinar? Email webinars@bnpmedia.com

Interested in conducting your own webinar? Email webinars@bnpmedia.com Interested in conducting your own webinar? Email webinars@bnpmedia.com Improving Efficiencies by Integrating Data Center Systems August 30 th, 2012 Audio Abstract Presenter Info Slides Handouts Group Chat

More information

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

Improving Rack Cooling Performance Using Airflow Management Blanking Panels Improving Rack Cooling Performance Using Airflow Management Blanking Panels By Neil Rasmussen White Paper #44 Revision 3 Executive Summary Unused vertical space in open frame racks and rack enclosures

More information

Control of Computer Room Air Handlers Using Wireless Sensors. Energy Efficient Data Center Demonstration Project

Control of Computer Room Air Handlers Using Wireless Sensors. Energy Efficient Data Center Demonstration Project Control of Computer Room Air Handlers Using Wireless Sensors Energy Efficient Data Center Demonstration Project About the Energy Efficient Data Center Demonstration Project The project s goal is to identify

More information

How To Run A Data Center Efficiently

How To Run A Data Center Efficiently A White Paper from the Experts in Business-Critical Continuity TM Data Center Cooling Assessments What They Can Do for You Executive Summary Managing data centers and IT facilities is becoming increasingly

More information

Direct Fresh Air Free Cooling of Data Centres

Direct Fresh Air Free Cooling of Data Centres White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The

More information

Data center upgrade proposal. (phase one)

Data center upgrade proposal. (phase one) Data center upgrade proposal (phase one) Executive Summary Great Lakes began a recent dialogue with a customer regarding current operations and the potential for performance improvement within the The

More information

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London. Energy Efficient Data Centre at Imperial College M. Okan Kibaroglu IT Production Services Manager Imperial College London 3 March 2009 Contents Recognising the Wider Issue Role of IT / Actions at Imperial

More information

Improving Data Center Efficiency with Rack or Row Cooling Devices:

Improving Data Center Efficiency with Rack or Row Cooling Devices: Improving Data Center Efficiency with Rack or Row Cooling Devices: Results of Chill-Off 2 Comparative Testing Introduction In new data center designs, capacity provisioning for ever-higher power densities

More information

Energy Impact of Increased Server Inlet Temperature

Energy Impact of Increased Server Inlet Temperature Energy Impact of Increased Server Inlet Temperature By: David Moss, Dell, Inc. John H. Bean, Jr., APC White Paper #138 Executive Summary The quest for efficiency improvement raises questions regarding

More information

Choosing Close-Coupled IT Cooling Solutions

Choosing Close-Coupled IT Cooling Solutions W H I T E P A P E R Choosing Close-Coupled IT Cooling Solutions Smart Strategies for Small to Mid-Size Data Centers Executive Summary As high-density IT equipment becomes the new normal, the amount of

More information