Data Center Context. Trends & Energy Use. Joshua Hatch Director, Sustainability Analytics Brightworks Sustainability Advisors
|
|
|
- August Walsh
- 10 years ago
- Views:
Transcription
1 Data Center Context Trends & Energy Use Joshua Hatch Director, Sustainability Analytics Brightworks Sustainability Advisors
2 Data Center Context Societal trends in business and individuals: Connectivity Ever faster bandwidth Wider availability More devices Streaming content Data and more Data Increasing Availability Increasing Quantity & Storage Increasing Reliance
3 Data Center Context Data centers are hidden behind: Living in the Cloud Storage Smart Phones Banking Calendars Leisure browsing ecommerce Shopping Entertainment Streaming Content Social News Business Health Care Government Telecommunication
4 Data Center Context Source:Koomey, Jonathon. Growth in Data Center Electricity Use Analytics Press
5 Data Center Context Worldwide, data center electrical energy use: DOUBLED from % Increase from Still, in 2010, they only represent: 1.3% of global electricity use 2% of US electricity use SOURCE: Koomey, Jonathon. Growth in Data Center Electricity Use Analytics Press
6 Data Center Context Types Enterprise Large owner/operator data centers Co-location Landlord/tenant, BYO-servers Cloud Data as service, rent bandwidth In-house Server closets in offices Key Considerations Uptime is king: 24 / 7 / 365 Redundancy Backup power Cooling-driven
7 Data Center Context Where do data centers want to be located? Cheap electricity High grid reliability Cheap large land plots Strong network/internet connection What do they look like? Large tilt up warehouses or renovations of industrial buildings Lots electrical lines, often cooling towers Rooftops packed with mechanical systems
8 Data Center Context Prioritizing Energy Efficiency Opportunities Location & Climate Electrical Distribution Servers Cooling Airflow Optimization Relevance in Oregon Inexpensive, high quality electricity No sales tax, economic development incentives Advantageous climate for free cooling
9 PART I: Overall Process, Model Geometry, and Internal Loads Aryn Bergman, P.E. TL CIRCLE
10 What s Important Differences b/t LEED and the ETO processes Establish the baseline Servers, cooling equipment, power distribution Support areas Depends on datacenter loads TL CIRCLE
11 Overall Workflow TL CIRCLE
12 Model Geometry TL CIRCLE
13 Calculating Power Distribution Efficiencies TL CIRCLE
14 Calculating Server Loads TL CIRCLE
15 Inputting Datacenter Loads into equest TL CIRCLE
16 Example EEM Savings TL CIRCLE
17 PART II: MODELING THE HVAC SYSTEMS BRIAN GOLDSMITH, LEED AP ALFA TECH
18 Data Center LEED Baseline Model Established by ASHRAE not suited for data centers Section G3.1.1 Exception equest is good for baseline model Usually just DX packaged units w/ little complexity Requires few or no spreadsheets
19 Data Center ETO Baseline Model Established by ETO New Buildings Program Technical Guidelines Dictated by State Energy Efficiency Design (SEED) Appendix L Based on ASHRAE Baseline model depends on proposed design Has provisions for evaporative cooling
20 Data Center Proposed Model equest cannot model modern data centers Limitations: SAT>70 High economizer cutoff Complicated Controls Evap cooling This is where Excel spreadsheets come in
21 Design Model Spreadsheets Excel is more powerful for these applications Add-in: PsychATCE VBA scripting and macros PsychATCE =RHfromDBWB(D4,E4,Elev) =DPfromDBWB(D4,E4,Elev) 8,760 hour TMY weather data from equest website Doe2.com/index_wth.html
22 Psych Chart Weather Data and Operating Modes 50 yr max wetbulb A:Mix OA/RA w/ Humid. B:100% OA w/ EC/H C:100% OA D:100% OA w/ Evap. Cool E1:100% OA w/ Evap. Cool and high DP E2:100% OA w/ Mech. Cool F: Mix OA/RA w/ high DP G:Mix OA/RA Data center operating criteria
23 Another Data Center Example Operating Window Max Wetbulb
24 Spreadsheet Input Screen Macros and buttons Almost all these values are calculated using PsychATCE Taken from schedules at full load not calculated Effectiveness used for evaporative cooling calc
25 Spreadsheet Calculation and Controls Sequence Supply Temp Reset Equation =IF(Y4,LADB_MIN,IF(OR(Z4,AB4,AC4),MIN(DBfromWBDP(E4,LADP_MIN,Elev)+FAN_HEAT,LADB_ MAX),IF(AA4,LADB_MAX,MAX(LADB_MIN,DBfromDPRH(H4,LARH_MAX,Elev)+FAN_HEAT))))
26 Detailed Calculation Example This is where evap. media effectiveness is factored in
27 Spreadsheet Output Screen Results broken down by operating mode No Mech Cooling Input into equest Calibrate equest to match
28 CLOSING POINTS Efficient servers and distribution systems have the most potential for savings Spreadsheet calculations can be used to demonstrate these savings Revit is a powerful tool for building modeling Be patient but persistent with LEED Learn how to use Excel Understanding psychrometrics and the controls sequence is key With the right tools and methodology, energy modeling can be used to improve data center mechanical system design efficiency.
Wet Bulb Temperature and Its Impact on Building Performance
Wet Bulb Temperature and Its Impact on Building Performance By: Kurmit Rockwell, PE, CEM, LEED AP and Justin Lee, PE, LEED, AP BD+C Energy Solution Services, AtSite, Inc. 1 What is Wet Bulb Temperature?
Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages
Objectives Increase awareness of the types of economizers currently used for data centers Provide designers/owners with an overview of the benefits and challenges associated with each type Outline some
IES <Virtual Environment> training. Trainee notes. ASHRAE 90.1 Appendix G - PRM Navigator. Version 6.4.0.7
IES training Trainee notes ASHRAE 90.1 Appendix G - PRM Navigator Version 6.4.0.7 Introduction These training notes are to be used in conjunction with your ASHRAE 90.1 Appendix G
AIRAH Presentation April 30 th 2014
Data Centre Cooling Strategies The Changing Landscape.. AIRAH Presentation April 30 th 2014 More Connections. More Devices. High Expectations 2 State of the Data Center, Emerson Network Power Redefining
CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers
CURBING THE COST OF DATA CENTER COOLING Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers OVERVIEW Compare Cooling Strategies in Free- Standing and In-Building
Guideline for Water and Energy Considerations During Federal Data Center Consolidations
Guideline for Water and Energy Considerations During Federal Data Center Consolidations Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory
Tips and Tricks for Estimating Energy Savings. Celeste Cizik, P.E. Project Manager E M C Engineers, Inc.
Tips and Tricks for Estimating Energy Savings Celeste Cizik, P.E. Project Manager E M C Engineers, Inc. AIA Quality Assurance Learning Objectives 1. Understand the pros and cons of various energy calculation
Greening Data Centers
Greening Data Centers Dallas Thornton SDSC Division Director, Cyberinfrastructure Services March 2, 2011 Data Centers Are Enormous Users of Power US Data Centers (TeraWatt Hours per Year) 125 US Televisions
Trends in Data Center Design ASHRAE Leads the Way to Large Energy Savings
Trends in Data Center Design ASHRAE Leads the Way to Large Energy Savings ASHRAE Conference, Denver Otto Van Geet, PE June 24, 2014 NREL/PR-6A40-58902 NREL is a national laboratory of the U.S. Department
Creating Credible, Actionable Energy Audits
1 Creating Credible, Actionable Energy Audits www.kw-engineering.com Jim Kelsey, PE kw Engineering What We ll Cover 2 Elements of ASHRAE Audit Levels 1, 2 and 3 Summary of audit levels On-site techniques
Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com
Cooling Small Server Rooms Can Be Inexpensive, Efficient and Easy - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com Server Rooms Description & Heat Problem Trends
Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks
Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same
Specialty Environment Design Mission Critical Facilities
Brian M. Medina PE Associate Brett M. Griffin PE, LEED AP Vice President Environmental Systems Design, Inc. Mission Critical Facilities Specialty Environment Design Mission Critical Facilities March 25,
CRITICAL COOLING FOR DATA CENTERS
IDEA 100 th Annual Conference & Trade Show CRITICAL COOLING FOR DATA CENTERS Presented by Ron Johanning, PE, LEED AP Mission Critical Market Leader Agenda EPA Report Data Center Energy Trends IT Best Practice
Best Practices in HVAC Design/Retrofit
Best Practices in HVAC Design/Retrofit Little Server Room BIG $AVINGS Justin Lewis, P.E., LEED AP, DCEP Sr Energy Project Manager C:530.400.6042 O:530.754.4870 [email protected] 1 What s the problem here?
Datacenter Clarity LC for colocation owners and tenants. The Data Center Infrastructure Management (DCIM) solution from Siemens. siemens.
Datacenter Clarity LC for colocation owners and tenants The Data Center Infrastructure (DCIM) solution from Siemens siemens.com/dcim Increased efficiency through Datacenter Clarity LC As organizations
FAQ' s. Frequently Asked Questions. A1 Control Units. Pge 1 of 7 PUMPKIN HOOK ROAD PO BOX OGD VAN HORNESVILLE NY 13475 USA 315-858-1002
Frequently Asked Questions FAQ' s A1 Control Units Pge 1 of 7 Table of Contents Q-1 Who are OGD and V-HVAC? 3 Q-2 Why do I need the A1 Control Unit and what are the benefits? 3 Q-3 How is the A1 Control
The Mission Critical Data Center Understand Complexity Improve Performance
The Mission Critical Data Center Understand Complexity Improve Performance Communications Technology Forum Fall 2013 Department / Presenter / Date 1 Rittal IT Solutions The State of the Data Center Market
Self-benchmarking Guide for Data Center Infrastructure: Metrics, Benchmarks, Actions 6-28-10. Sponsored by:
Self-benchmarking Guide for Data Center Infrastructure: Metrics, Benchmarks, Actions 6-28-10 Sponsored by: Disclaimer This document was prepared as an account of work sponsored by the United States Government.
HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow
HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation Richard Lord Carrier Fellow HVAC Industry Challenges and Issues Ozone Deletion Global Warming
High Altitude HVAC. Silvertip Integrated Engineering Consultants [email protected] www.silvertipconsultants.com
Presentation to: Rocky Mountain ASHRAE 2013 Tech Conference April 19, 2013 High Altitude HVAC Design Considerations by: Michael D. Haughey, PE, HBDP, CEM, LEED TM AP 2013 Silvertip Integrated Engineering
UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
Data Centre Cooling Technologies. Jon Pettitt, EMEA DataCenter Business Development Manager
Data Centre Cooling Technologies 1 Jon Pettitt, EMEA DataCenter Business Development Manager Munters Group Key facts 3.000 Employees 30 Countries Turnover of 470 M HQ in Sweden Global DC Support 25+ Data
THE WORLD S MOST EFFICIENT DATA CENTER
THE WORLD S MOST EFFICIENT DATA CENTER HP POD 240a Ed Turkel Manager, WW HPC Marketing Hyperscale Business Unit 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject
Green Data Centre Design
Green Data Centre Design A Holistic Approach Stantec Consulting Ltd. Aleks Milojkovic, P.Eng., RCDD, LEED AP Tommy Chiu, EIT, RCDD, LEED AP STANDARDS ENERGY EQUIPMENT MATERIALS EXAMPLES CONCLUSION STANDARDS
DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER
DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTERS 2009 IT Emissions = Aviation Industry Emissions Nations Largest Commercial Consumers of Electric Power Greenpeace estimates
Datacenter Efficiency Program
Datacenter Efficiency Program Yuming Qiu, CLEAResult Anna Stieve, CLEAResult Michael Stachowiak, CLEAResult Abstract Worldwide, datacenter energy consumption is skyrocketing and datacenter energy efficiency
CIBSE ASHRAE Group. Data Centre Energy Efficiency: Who, What, Why, When, Where & How
CIBSE ASHRAE Group Data Centre Energy Efficiency: Who, What, Why, When, Where & How Presenters Don Beaty PE, FASHRAE Founder, President & Managing Director DLB Associates Consulting Engineers Paul Finch
Green Data Centers. Energy Efficiency Data Centers. André ROUYER Director of Standardization & Environment. The importance of standardization
Green Data Centers GOING FORWARD ENERGY EFFICIENCY TRENDS André ROUYER Director of Standardization & Environment All content in this presentation is protected 2008 American Power Conversion Corporation
Colocation Hosting Primer Making the Business and IT Case for Colocation
Where every interation matters. Colocation Hosting Primer Making the Business and IT Case for Colocation White Paper February 2012 By: Peer 1 Hosting Product Team www.peer1.com Contents Overview 3 Why
Data Centers: How Does It Affect My Building s Energy Use and What Can I Do?
Data Centers: How Does It Affect My Building s Energy Use and What Can I Do? 1 Thank you for attending today s session! Please let us know your name and/or location when you sign in We ask everyone to
MOVING INTO THE DATA CENTRE: BEST PRACTICES FOR SUCCESSFUL COLOCATION
MOVING INTO THE DATA CENTRE: BEST PRACTICES FOR SUCCESSFUL COLOCATION CONTENTS Overview _ 2 FINDING THE RIGHT DATA CENTRE FOR YOUR BUSINESS _ 3 PREPARING FOR THE MOVE 6 MAKING THE MOVE _ 8 summary _ 9
Data Centers That Deliver Better Results. Bring Your Building Together
Data Centers That Deliver Better Results Bring Your Building Together 1 Meeting the high demands of your data center Meeting the increasing heat loads associated with growing computational needs requires
Chilled Water System Commissioning: Variable Primary Flow. John D. Villani, P.E. Associate Grumman/Butkus Associates
Chilled Water System Commissioning: Variable Primary Flow John D. Villani, P.E. Associate Grumman/Butkus Associates AIA Quality Assurance Learning Objectives 1. History of chilled water system configurations
Data Center Design and Energy Management
Agenda EasyStreet Online Services, Inc. Data Center Design and Energy Management Introduction to EasyStreet Speaker Bio EasyStreet Sustainability Data Center 1 (Retrofit completed May 2010) Data Center
Todd M. Rossi, Ph.D. President
Residential Air Conditioning Fault Detection and Diagnostics (FDD) and Protocols to Support Efficient Operation DOE - Building America Program Residential Buildings Integration Meeting - July 20-22, 2010
Sage X3 in the Cloud. Business Benefits
X3 Sage X3 in the Cloud provides your enterprise with a remote and secure access to a complete and hosted ERP solution with monthly payment per user and no further investment in terms of Hardware and IT
Legacy Data Centres Upgrading the cooling capabilities What are the options?
Legacy Data Centres Upgrading the cooling capabilities What are the options? Presentation Structure What is a Legacy Data Centre? What is CRAC cooling? ASHRAE Standards Overview Available Cooling Systems
(Examples of various colocation sites)
Overview The largest factor involved in maintaining business servers today are the fixed costs associated with data centers. The Colocation Environment is an outsourcing model whereby a colocation company
Increasing Energ y Efficiency In Data Centers
The following article was published in ASHRAE Journal, December 2007. Copyright 2007 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes
Top 5 Trends in Data Center Energy Efficiency
Top 5 Trends in Data Center Energy Efficiency By Todd Boucher, Principal Leading Edge Design Group 603.632.4507 @ledesigngroup Copyright 2012 Leading Edge Design Group www.ledesigngroup.com 1 In 2007,
CCA Fall 2012. Karl Erik Rye. Director, Comm. Products, GCI. [email protected]
The Cloud (Enabler for Service Providers to Supply More to Their Customers) A Regional Carrier Perspective CCA Fall 2012 Karl Erik Rye Director, Comm. Products, GCI [email protected] Data Center in the Cloud
PROJECTING ANNUAL NEW DATACENTER CONSTRUCTION MARKET SIZE. By Christian L. Belady, P.E.
PROJECTING ANNUAL NEW DATACENTER CONSTRUCTION MARKET SIZE By Christian L. Belady, P.E. GLOBAL FOUNDATION SERVICES MARCH 2011 Author s Note: this work is intended to be an exercise to estimate the size
Data Centers in Hong Kong Powering business success
Data Center Data Centers in Hong Kong Powering business success NTT Com Asia DATA CENTERS IN HONG KONG INDUSTRY-LEADING DATA CENTER SERVICES WITH GLOBAL FOOTPRINTS. NTT Communications offers data center
Environmental Data Center Management and Monitoring
2013 Raritan Inc. Table of Contents Introduction Page 3 Sensor Design Considerations Page 3 Temperature and Humidity Sensors Page 4 Airflow Sensor Page 6 Differential Air Pressure Sensor Page 6 Water Sensor
National Grid Your Partner in Energy Solutions
National Grid Your Partner in Energy Solutions National Grid Webinar: Enhancing Reliability, Capacity and Capital Expenditure through Data Center Efficiency April 8, 2014 Presented by: Fran Boucher National
Data Center Facility Basics
Data Center Facility Basics Ofer Lior, Spring 2015 Challenges in Modern Data Centers Management, Spring 2015 1 Information provided in these slides is for educational purposes only Challenges in Modern
Catalyst RTU Controller Study Report
Catalyst RTU Controller Study Report Sacramento Municipal Utility District December 15, 2014 Prepared by: Daniel J. Chapmand, ADM and Bruce Baccei, SMUD Project # ET13SMUD1037 The information in this report
COMMODITIZING THE DATACENTER. Exploring the Impacts of the Shift to Virtualization and Cloud Computing
COMMODITIZING THE DATACENTER Exploring the Impacts of the Shift to Virtualization and Cloud Computing 3/5/2015 AGENDA Changing Environments What Is The Datacenter Why Do We Use Them Adapting To A Changing
AIA Provider: Colorado Green Building Guild Provider Number: 50111120. Speaker: Geoff Overland
AIA Provider: Colorado Green Building Guild Provider Number: 50111120 Office Efficiency: Get Plugged In AIA Course Number: EW10.15.14 Speaker: Geoff Overland Credit(s) earned on completion of this course
Topics. Database Essential Concepts. What s s a Good Database System? Using Database Software. Using Database Software. Types of Database Programs
Topics Software V:. Database concepts: records, fields, data types. Relational and objectoriented databases. Computer maintenance and operation: storage health and utilities; back-up strategies; keeping
Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal
Technical Bulletin By Bruce I. Nelson, P.E., President, Colmac Coil Manufacturing, Inc. Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal SUMMARY Refrigeration air coolers (evaporators)
Guide to Minimizing Compressor-based Cooling in Data Centers
Guide to Minimizing Compressor-based Cooling in Data Centers Prepared for the U.S. Department of Energy Federal Energy Management Program By: Lawrence Berkeley National Laboratory Author: William Tschudi
Data Centre Outsourcing a Buyer s Guide
Data Centre Outsourcing a Buyer s Guide The inside guide to deciding whether to outsource your data centre facility and operations and how to select an appropriate partner. This Guide will help you Determine
TRANSFORM METRICS TO MANAGEMENT AND REALIZE BUILDING POTENTIAL
TRANSFORM METRICS TO MANAGEMENT AND REALIZE BUILDING POTENTIAL 02 www.coppertreeanalytics.com Realize building potential REALIZE YOUR BUILDING POTENTIAL The promise of smart buildings was that automation
Using Industrial Ethernet Switches to Assure Maximum Uptime White Paper
Six Best Practices for Effective Wind Farm Operation Using Industrial Ethernet Switches to Assure Maximum Uptime White Paper Six Best Practices for Effective Wind Farm Operation Using Industrial Ethernet
How To Test A Theory Of Power Supply
A CASE STUDY ON: THE EFFECTS OF HIGHER OPERATING TEMPERATURES ON DATA CENTER EFFICIENCY Victor Garcia Director of Facilities Brocade October 24, 2012 Jeff Stein, PE Principal Taylor Engineering 2010 Brocade
Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling
Data Center Design Guide featuring Water-Side Economizer Solutions with Dynamic Economizer Cooling Presenter: Jason Koo, P.Eng Sr. Field Applications Engineer STULZ Air Technology Systems jkoo@stulz ats.com
Datacenter Efficiency
EXECUTIVE STRATEGY BRIEF Operating highly-efficient datacenters is imperative as more consumers and companies move to a cloud computing environment. With high energy costs and pressure to reduce carbon
for K-12 School Buildings
Advanced Energy Design Guide for K-12 School Buildings HVAC Section John Murphy Applications Engineer, LEED AP Trane La Crosse, Wisconsin [email protected] www.trane.com AEDG-K12 HVAC Subcommittee John
Defining Quality. Building Comfort. Precision. Air Conditioning
Defining Quality. Building Comfort. Precision Air Conditioning Today s technology rooms require precise, stable environments in order for sensitive electronics to operate optimally. Standard comfort air
611 Tradewind Dr. Suite 100, Ancaster ON, L9G 4V5 (905) 304-1775 ext 244 [email protected]
Connecting To The Cloud Is Easier Than You Think Audcomp Cloud Services can bring your organization into the cloud. We provide a secure reliable medium to maximize your uptime, allowing you to focus on
Energy Savings in High-Rise Buildings Using High-Reflective Coatings
Energy Savings in High-Rise Buildings Using High-Reflective Coatings Executive Summary: Nevertheless, the simulation analyses showed that when designing a building for low energy consumption, even in cold
Data Center Commissioning: What you need to know
Data Center Commissioning: What you need to know Course # CXENERGY1511 AIA Provider # 50111116 AABC Commissioning Group CxEnergy Conference Henderson, NV April 30, 2015 Presented by: Judson H. Adams, P.E.,
Indirect Evaporative Cooling (IDEC) Unit for Data Centers
Indirect Evaporative Cooling (IDEC) Unit for Data Centers NORTEK AIR SOLUTIONS Cool3 IDEC UNIT INDIRECT EVAPORATIVE COOLING The new Nortek Air Solutions Cool 3 IDEC unit is a proven approach for highly
Technical Analysis Document
Technical Architecture Technical Analysis Document The table below shows the various possibilities that sonic sounds have to host their e-commerce site on. The hosting type is described and then advantages
How To Choose A Cloud Based Erp System From Microsoft.Com
Brought to you by: 35 Questions Every CFO Needs to Ask About ERP Software In the Cloud The ERP Software Blog is proud to bring you The ERP PANEL PAPERS A straightforward series of white papers from a nationwide
In Row Cooling Options for High Density IT Applications
In Row Cooling Options for High Density IT Applications By Ramzi Y. Namek, PE, LEED AP, BD+C; Director of Engineering 1 Users wishing to deploy high density IT racks have several In Row Cooling solutions
Using Time-of-Day Scheduling To Save Energy
The following article was published in ASHRAE Journal, May 29. Copyright 29 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. It is presented for educational purposes only.
Dr. Michael K. West, PE 1 Dr. Richard S. Combes, PE 2 Advantek Consulting / Melbourne, Florida
Optimizing 100% Outside Air Systems with Heat Pipes Dr. Michael K. West, PE 1 Dr. Richard S. Combes, PE 2 Advantek Consulting / Melbourne, Florida Introduction To meet increasingly rigorous building codes
ES 106 Laboratory # 6 MOISTURE IN THE ATMOSPHERE
ES 106 Laboratory # 6 MOISTURE IN THE ATMOSPHERE 6-1 Introduction By observing, recording, and analyzing weather conditions, meteorologists attempt to define the principles that control the complex interactions
Introducing AUDIT-BUDDY
Introducing AUDIT-BUDDY Optimize the Data Center with AUDIT-BUDDY Executive Summary Proper temperature and humidity for the inlet air into the servers is essential to efficient data center operation. Several
Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia
Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia Prepared for the U.S. Department of Energy s Federal Energy Management Program
How to Build a Data Centre Cooling Budget. Ian Cathcart
How to Build a Data Centre Cooling Budget Ian Cathcart Chatsworth Products Topics We ll Cover Availability objectives Space and Load planning Equipment and design options Using CFD to evaluate options
IDC FutureScape: Worldwide Datacenter 2016 Predictions. IDC Web Conference November 2015
IDC FutureScape: Worldwide Datacenter 2016 Predictions IDC Web Conference November 2015 Logistics Today s Speakers Submit any questions to [email protected] You can download slides from the Resource
Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis
Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis Sophia Flucker CEng MIMechE Ing Dr Robert Tozer MSc MBA PhD CEng MCIBSE MASHRAE Operational Intelligence Ltd. [email protected]
AGENDA ITEM BACKGROUND TO: GOVERNING BOARD ITEM NUMBER
TO: GOVERNING BOARD AGENDA ITEM BACKGROUND DATE FROM: PRESIDENT SUBJECT: Information Technology Update April 11, 2011 ENCLOSURE(S) REASON FOR BOARD CONSIDERATION INFORMATION Storage Area Network (SAN)
Building Analytics Improve the efficiency, occupant comfort, and financial well-being of your building.
Building Analytics Improve the efficiency, occupant comfort, and financial well-being of your building. Make the most of your energy SM Building confidence knowing the why behind your facility s operations
CASE STUDY: COOLERADO CORPORATION
CASE STUDY: COOLERADO CORPORATION Coolerado uses Weather Analytics climate data to demonstrate to clients the energy-efficiency of their air conditioners in places around the globe. 02 Overview Coolerado
Green Data Center: Energy Reduction Strategies
Federal Energy ManagEment Program Green Data Center: Energy Reduction Strategies Airside Economization and Unique Indirect Evaporative Cooling Executive summary The Green Data Center Project was a successful
HOURLY ANALYSIS PROGRAM QUICK REFERENCE GUIDE
HOURLY ANALYSIS PROGRAM QUICK REFERENCE GUIDE COPYRIGHT 1998-2015 CARRIER CORPORATION [This page has been left blank intentionally] HAP Quick Reference Guide Software Systems Network Carrier Corporation
CONTROL STRATEGIES FOR HVAC SYSTEMS
CONROL SRAEGIES FOR HVAC SYSEMS ZBIGNIEW POPIOLEK Department of Heating, Ventilation and Dust Removal echnology Silesian University of echnology, Poland 1 Definition of control: to apply a regulating influence