Rated Lumen [lm] Nominal. Volts [V] [lm]
|
|
|
- Cameron Lindsey
- 9 years ago
- Views:
Transcription
1 GE Lighting rcstream Metal Halide lamps Tubular Clear 25W and W Elliptical Diffuse 25W DT SHEET Product information High brightness, high quality white light with good colour rendition and energy efficiency makes GE Metal Halide lamps suitable for many commercial and industrial interiors, particularly in high ceiling areas. pplication areas Office Commercial reas Industrial Car Park asic data Product Code Product Description Nominal Rated Weighted Energy Consumption [kwh/1 hrs] Volts [V] Nominal Cap Lumen [lm] Rated Lumen [lm] Rated Lamp Efficacy [lm/w] Energy Efficiency Class (EEC) CCT [K] Colour Rendering Index [Ra] Mercury Content [mg] mbient Temperature [ C] rcstream Elliptical Diffuse 347 RC 25/D/H/96/E E 17, 15, , RC 25/D/VU/96/E E 17, 17,8 64 6, RC 25/D/H/7/E E 19,5 21,2 79 4, rcstream Tubular Clear RC 25/T/H/742/E E 21, 22, , RC 25/T/VU/96/E E 19, 19, , RC 25/T/H/96/E E 19, 19, , RC 25/T/H/96/E MIC E 19, 19, , RC /T/H/742/E E 35, 35, ,
2 Dimensions C C Product code Figure 1. Figure 2. Figure 3. Length [mm] Diameter [mm] C LCL (mm) Cap Operating Position varage Rated Life [h] ulb Glass Mass [g] Minimum Starting Temperature [ C] rcstream Elliptical Diffuse E Hor. ±15 1. Hard E V ase Up ±45 1. Hard E Hor. ± Hard rcstream Tubular Clear E Hor. ±15 1. Hard E V ase Up ±45 1. Hard E Hor. ±45 1. Hard E Hor. ±45 1. Hard E Hor. ±15 1. Hard Figure Survival rate and lumen maintenance The graph shows survival of representative groups of lamps operated under control conditions at 1 hours per start. Lamp life in service will be affected by a number of parameters, such as mains voltage variation, switching cycle, luminaire design and control gear. The information given is intended to be a practical guide in determining lamp replacement schedules. 1 rcstream W lamps 1 rcstream 25W lamps 8 8 % of initial 6 % of initial 6 2 Survival rate Lumen maintenance 2 Survival rate Lumen maintenance urning time (thousand hours) urning time (thousand hours) 2
3 Spectral power distribution 5 K natural white spectral power distribution 5 6K daylight spectral power distribution Relative intensity Relative intensity nm Wavelength nm Wavelength Operating note Metal halide lamps operate with a high internal pressure and there is a slight risk that lamps may shatter, particularly if run beyond rated life. t end of life a switch off should be introduced every 24 hrs to reduce the risk of shattering. The lamp must be fully enclosed by a luminaire to ensure the retention of any fragments in the event of such failure. Electrical data Data is based on a nominal lamp operating from a nominal choke (reactor) ballast with power factor correction. Supply power is based on a typical commercially available ballast. Tubular Clear Volts ±15 [V] Current [] Power Maximum Current Crest Factor Elliptical Diffuse Run-up characteristics The graph shows typical run-up characteristics. Time for the light output to reach 9% of the final value is determined by supply voltage and ballast design. Percentage of final value Typical run-up characteristics Time from switch-on (minutes) Lamp current Supply current Supply power Lamp power Lamp Volt age Light output Hot re-strike time ll ratings re-strike within 7 minutes following a short interruption in the supply. ctual re-strike time is determined by ignitor type, pulse voltage and cooling rate of the lamp. 3
4 Supply voltage 25W and W lamps are suitable for supplies in the range 22V to 25V and 1W lamps for supplies in the range 38 to 415V; 5/6Hz for appropriately rated series choke (reactor) ballasts. Supplies outside this range require a transformer (conventional, high reactance or CW) to ensure correct lamp operation. Lamps start and operate at 1% below the rated supply voltage when the correct control gear is used. However, in order to maximise lamp survival, lumen maintenance and colour uniformity the supply voltage and ballast design voltage should be within ±3%. Supply variations of ±5% are permissible for short periods only. This may be achieved by measuring mean supply voltage at the installation and selecting ballasts with appropriate settings. Effect of supply voltage variation 12 % change from nominal Lamp voltage Lamp current Lamp wattage Lamp lumens Percentage of rated supply voltage Control gear There are no international standards for metal halide lamps of this type. It is therefore important to check the compatibility of lamp and control gear. Detailed information is given in this data sheet under Guidance for luminaire manufacturers. It is essential to use a ballast appropriate to the supply voltage at the luminaire. Typical wiring diagrams for control circuits incorporating a Superimposed or Impulser ignitor and choke (reactor) ballast are shown. Refer to actual ballast and ignitor manufacturer s data for terminal identification and wiring information. Fusing of circuits number of factors need to be taken into account when selecting the rating and characteristic of the supply line fuse/mc: (a) t the instant the circuit is switched-on, PFC capacitor current can be many times the steady state value for a very short period (few hundred microseconds). (b) For a short period (few seconds) after switch-on all discharge lamps may act as a partial rectifier and as a result the ballast can allow several times the normal supply current to flow. (c) During the lamp run-up period supply current is higher than normal (see graph). Watts Tubular Clear Elliptical Diffuse Typical superimposed ignitor circuit Typical impulser ignitor circuit PHSE LLST PHSE LLST PFC Capacitor IGNITOR Lp N PFC Capacitor IGNITOR Lp N NEUTRL NEUTRL 4
5 Guidance for luminaire manufacturers Lamp operating temperature limits Maximum Cap Temperature: 25 C Maximum ulb Temperature: 45 C Control gear To achieve correct lamp starting, performance and life it is important that lamp and control gear are compatible and suitably rated for the supply voltage at the luminaire. allasts Lamps are fully compatible with ballasts manufactured for high pressure sodium lamps to IEC6662 and for metal halide lamps to IEC Enhanced performance can be achieved by using special ballasts to the specification shown below. 1W lamps operate between phases and require special ballasts. allasts should comply with specifications IEC and IEC6923. Series choke (reactor) ballasts should have characteristics close to the following values: Supply Voltage 22V 23V 2V 25V Tubular Clear 25W Impedance at 3 (ohms ) ased on Cold Watts loss (W) Tubular Clear W Impedance at 4.6 (ohms ) ased on Cold Watts loss (W) Elliptical Clear & Coated 25W Impedance at 3 (ohms ) ased on Cold Watts loss (W) allast thermal protection Use of ballasts incorporating thermal cut-out is not a specific requirement but is a good optional safety measure for the installation. allast voltage adjustment Series choke (reactor) ballasts incorporating additional tappings at ±1V of the rated supply voltage are recommended. lternatively a single additional tapping 1V above the rated supply voltage will ensure lamps are not overloaded due to excessive supply voltage. Ignitors oth Superimposed and Impulser type ignitors are suitable. It is recommended that only GE approved ignitors are used. Ignitors should comply with specifications IEC and IEC6927 and have starting pulse characteristics as follows: Watts Min Pulse Max Pulse Voltage (kv) 1 Voltage (kv) 2 Min Pulse Width (µs) 3 Min Pulse Repetition Rate 4 Min HF Peak Current [] >.3 3 / half cycle > >.3 3 / half cycle > >.3 1 / half cycle >1 1. When loaded with 1 pf. 2. When loaded with 2pF. 3. t 9% peak voltage. 4. From ignitor into lamp during starting. Timed ignitors Use of a timed or cut-out ignitor is not a specific requirement, but it is a good optional safety feature for the installation. The timed period must be adequate to allow lamps to cool and restart when the supply is interrupted briefly (see hot re-strike time ). period of 5 minutes continuous or intermittent operation is recommended before the ignitor is automatically switched off. Commercially available 1/11 minute timed ignitors are suitable. 5
6 Cable between ignitor and lamp Cable connected between the lamp and a superimposed ignitor Lp terminal, or the ballast when using an impulser ignitor, must be rated at a minimum 5/6Hz voltage of 1V. Mineral insulated cable is not suitable for connecting the lamp to the control gear. To achieve good starting superimposed ignitors must be adjacent to the luminaire. Cable capacitance of wiring between the ignitor Lp terminal and the lamp should not exceed 1pF (<1 metre length) when measured to adjacent earthed metal and/or other cables, unless otherwise stated by ignitor manufacturer. When using impulser type ignitors longer cable lengths between ballast and lamp are normally permissible. Limits for particular ignitors are available on request from GE Lighting or directly from the ignitor manufacturer. PFC capacitors for simple choke circuits Power Factor Correction is advisable in order to minimise supply current and electricity costs. For 22-25V supplies 25V±1% rated capacitors are recommended as follows: Tubular Clear 25W W PFC Capacitor 3µF µf Elliptical Diffuse PFC Capacitor 3µF - and General Electric are both registered trademarks of the General Electric Company GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this brochure are intended as a general guide, and we may change specifications from time to time in the interest of product development, without prior notification or public announcement. ll descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability arising from the reliance on such data to the extent permitted. rcstream Tubular & Elliptical Data Sheet June 216
Multi-Vapor Metal Halide Lamps
GE Lighting Multi-Vapor Metal Halide Lamps Elliptical Clear 175W, 250W, 400W and 00W Elliptical Diffuse 175W, 250W and 400W High Output Elliptical Clear & Diffuse 250W and 400W DATA SHEET Product information
Kolorlux. GE Lighting DATA SHEET
GE Lighting Kolorlux High pressure Mercury lamps Kolorlux Standard 50W, 80W, 125W, 250W and 400W Kolorlux Deluxe 50W, 80W, 125W, 250W and 400W DATA SHEET Product information Kolorlux Mercury vapor lamps
Applications. Architectural
GE Lighting Arcstream Single Ended Metal Halide lamps 7W and 15W DATA SHEET Product information Arcstream Single Ended lamp consists of a compact high pressure metal halide discharge operating in a quartz
T5 LongLast. GE Lighting DATA SHEET
GE Lighting T5 LongLast DATA SHEET Linear Fluorescent Lamps T5 LongLast High Efficiency 14W, 21W, 28W, 35W T5 LongLast High Output 24W, 39W, 49W, 54W, 8W Product information T5 LongLast lamps are triphosphor
Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.
GE Lighting Biax S and S/E Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W DATA SHEET information Biax S compact fluorescent lamps can provide savings of up to 73% in energy costs compared
T5 Watt-Miser Linear Fluorescent lamps
GE Lighting T5 Watt-Miser Linear Fluorescent lamps DATA SHEET T5 Watt-Miser High Efficiency 13W, 20W, 26W, 33W T5 Watt-Miser High Output 21W, 36W, 46W, 51W, 76W Product information T5 Watt-Miser lamps
ConstantColor CMH MR16
GE Lighting ConstantColor CMH MR16 Reflector Ceramic Metal Halide Lamps W and 35W DATA SHEET Product information ConstantColor CMH lamps combine HPS technology (providing stability, efficiency & uniformity)
GE ConstantColor CMH Precise MR16 20 & 35W
GE Lighting GE ConstantColor CMH Precise MR16 2 & 35W DATA SHEE T TECHNOLOGY ConstantColor CMH lamps combine HPS technology (providing stability, efficiency & uniformity) and Metal Halide Technology (providing
High Pressure Mercury
High Pressure Mercury E27 B Product Description Mixed Light lamps Product Features High-pressure mercury tube in series with a tungsten filament Runs on mains voltage without additional gear Combines a
The most sustainable lighting solution. QL 85W Induction Lighting System
The most sustainable lighting solution QL 85W Induction Lighting System QL Induction Lighting Systems QL induction lighting is used for professional, general and special lighting applications because of
DuroSite TM High Bay Lighting
DuroSite TM High Bay Lighting LED White Lighting Brochure for Industrial Applications CE version Application: The first of its kind, the Dialight DuroSite TM LED High Bay luminaire was designed specifically
LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens 270-1250 CLASSIC umodule QLE
Umodule STARK QLE G3 lens 27-125 CLASSIC umodule QLE Product description Ideal for linear and panel lights Luminous flux range from 1, 1,21 lm LED system solution with outstanding system efficacy up to
Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.
GE Lighting Biax T/E Triple Biax Compact Fluorescent Lamps Non-Integrated W, W, W, 32W and 42W Product description Ultra compact energy saving CFL lamps with triple-tube design give an ideal light source
Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W
T5 TC-DEL TC-SEL TC-TEL TC-DD PC BASIC, 4 28 W Electronic ballast for system output < 25 W Product description CELMA Energy Efficiency Index A2 / A3 Nominal life time up to 50,000 h (at ta 50 C with a
Metal Halide Pulse Start vs. Probe Start. By Dick Erdmann GE Specification Engineer
Pulse Start vs. Probe Start By Dick Erdmann GE Specification Engineer As we enter this new age of energy awareness, the lighting community has been at the forefront finding more and more ways to conserve
PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, 18 80 W Compact and T5c fluorescent lamps
Product description Noise-free precise control via DSI signal or switchdim CELMA energy class A1 1) Interfaces DSI switchdim Integrated SMART-Interface Functions Optimum filament heating in any dimmer
EPL225 Series. 225 Watts. www.xppower.com. AC-DC Power Supplies. Models & Ratings. Summary
225 Watts 50 W Convection/ 225 W Forced-cooled Ratings 2 by 4 Footprint Low.26 Profile 2 V Fan Output High Efficiency, up to 95% ITE & Medical pprovals High Power Density Less than 0.5 W No Load Input
PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, 18 80 W Compact and T5c fluorescent lamps
EXCEL oneall series Product description Noise-free precise control via DSI signal, switchdim, corridorfunction or DALI DALI-MEMORY Extended DALI commands CELMA energy class A1 1) Interfaces DALI DSI switchdim
FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, 14 80 W BASIC T5
T5 TC-L PCA T5 BASIC lp Y II, 1 80 W BASIC T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DSI signal,
Linear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
LED light engine / OLED LED compact. Umodule STARK CLE 120-2000 CLASSIC / CLE 130-2500 CLASSIC umodule CLE
Umodule STARK CLE 12-2 CLASSIC / CLE 13-25 CLASSIC umodule CLE Product description Designed for diffuser downlights and wallmounted luminaires Ideal to realise simple luminarie designs For easy adaptation
LUXEON TX Extreme efficacy that will transform your next market leading luminaire
LUXEON TX Extreme efficacy that will transform your next market leading luminaire Introduction LUXEON TX emitters are illumination grade LEDs designed to deliver high efficacy with high flux density to
PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE
w LED light engine / OLED Product description For general lighting application Typ. luminous flux category: 3/6/8/1,2 lm High efficacy up to 133 lm/w for the LED module at tp = 25 C Small LES (light emitting
Kit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
GE Lighting. Spectrum Catalogue 2013/14
GE Lighting Spectrum Catalogue Lamp PRODUCTS 2013/14 GE imagination at work www.gelighting.com GE Lighting Spectrum Lamp product catalogue 2013/14 GE Lighting is constantly developing and improving its
Photosynthesis Light for Horticulture
Photosynthesis Light for Horticulture Horticulture Lamps Lighting for growth Lamps and lighting for horticulture Properly balanced Improves Specially developed More PAR Stable Wide range blue and red colours
Nominal Power [W] Radiance Angle [ ] Color Temp. [K]
PrevaLED COIN 111 G2 Technical Information Benefits Fits in most existing R111 traditional luminaires Easy & fast design-in for luminaire manufacturers Narrow beam angles, 24 o and 40 o High lumen output
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
FL ballasts Electronic dimming. PCA T5 ECO lp Y II, 14 80 W ECO T5
EL PCA ECO lp Y II, 1 80 W ECO Product description Processor-controlled ballast with y II inside Highest possible energy class CELMA EEI = A1 BAT 1 Noise-free precise control via DALI or DSI signal, switchdim
Vehicle Circulation Areas - OPT 3 (Rev 00)
Vehicle Circulation Areas - OPT 3 (Rev 00) Customer : TACE (Nick Thomas) Processed by : Matt Booth (on behalf of Andrew Glaister) Project description: Rev 00 (14.11.2012) This OPTION 3 calculation has
(Refer Slide Time: 00:01:43 min)
Illumination Engineering and Electric Utility Services Prof. N.K. Kishore Department of Electrical Engineering Indian Institute of Technology, Kharagpur Lecture No. # 9 Discharge Lamps II Welcome to the
OSRAM DULUX SUPERSTAR MICRO TWIST
OSRAM DULUX SUPERSTAR MICRO TWIST Compact fluorescent integrated, spiral shape Areas of application _ Wherever compact and efficient lamps are needed _ High-quality domestic and professional environments
High flux for outdoor applications
General Illumination LUXEON R High flux for outdoor applications LUXEON R brings illumination grade LED light sources to outdoor and industrial lighting applications and makes it easier than ever to design
LINEAR SYSTEM 3000K 4000K 5000K 6000K 7000K
Tunable White Brightness dimmable RGB adjustable 2500K - 7000K 5% - Colours and sequences Biorhythmic lighting Vitalisation and Recreation 2 control modes Excellent CRI DALI DT8, NeoLink CRI>90 2500K 7000K
Features. High Brightness LED Light source
www.edison-opto.com Solid-State Lighting Series 6W MR16 DATASHEET Features High Brightness LED Light source Ecologically Friendly Energy Efficient General Information... 1 Product Dimensions... 2 Product
DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications. www.dialight.com
DuroSite TM Series LED High Bay Brochure for Industrial & Commercial Applications.dialight.com 1 DuroSite TM Series LED High Bay Features & Benefits 80% lumen maintenance after 60,000 hours Up to 79lm/
EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES
EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES Gas explosion protection II 2G Ex d IIC T6 Gb (suitable for Zone1 and Zone 2) Dust explosion protection II 2D Ex tb IIIC
FILM CAPACITORS FOR ELECTRONIC LIGHTING
1. Introduction: FILM CAPACITORS FOR ELECTRONIC LIGHTING G. Schabbach, Dr. K. Weigel, Dr. G. Zimmermann EPCOS AG Fluorescent lamps have emerged as the preferred light source for industrial and domestic
Section D..General Auto Electrical Corporation
43 Section D..General Auto Electrical Corporation 1. LED Based Signal unit GAEC manufacture LED based signaling system for use in electrified and non electrified sections of Indian railways. The exceptional
Power Supplies. 1.0 Power Supply Basics. www.learnabout-electronics.org. Module
Module 1 www.learnabout-electronics.org Power Supplies 1.0 Power Supply Basics What you ll learn in Module 1 Section 1.0 Power Supply Basics. Basic functions of a power supply. Safety aspects of working
www.osram.com Guide to Starters Guide to Starters Page 1 of 17
www.osram.com Guide to Starters Guide to Starters Page 1 of 17 Guide to starters 1 Contents 1 Contents... 2 2 Introduction... 4 3 Definitions (important technical parameters of a starter)... 4 3.1 Partial
GE Lighting. Lighting the future. Your guide to changing to energy efficient lamps
GE Lighting Lighting the future Your guide to changing to energy efficient lamps Out with ordinary light bulbs In with energy efficient lamps Classic incandescent light bulbs have been gradually phased
2D and 2D Watt-Miser. GE Lighting DATA SHEET. Compact Fluorescent Lamps Non-Integrated 16, 21, 28, 38W 2D Watt-Miser and 55W 2D. Product information
GE Lighting 2D and 2D Watt-Miser Compact Fluorescent Lamps Non-Integrated 16, 21, 28, 38W 2D Watt-Miser and 55W 2D DATA SHEET information Biax 2D compact fluorescent lamps have been available for many
3-phase, bidirectional energy meter
Data sheet www.sbc-support.com 3-phase, bidirectional energy meter with S0 pulse output Bidirectional energy meter with S0-interface. The S0 interface is a hardware interface for the transmission of measured
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Product specifications
The Washer Allegro AC XB is a compact, AC line powered high brightness luminaire. The series is phase-cut dimmable, and is available in color temperatures 3000K / 4000K and optics. The simplicity of the
LINEA 120 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 60 EN60598 / EN62031 / EN62471.
LINEA 120 FIXED ECO solution Ø 180 mm Specifications LINEA 120 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 60 Fixture Material Diecast Aluminium Environment/Applications
LED light engine / OLED LED linear /area. Umodule STARK LLE-24-560-1300 CLASSIC STARK LLE. Ordering data
Ideal for linear and panel lights Luminous flux range from 1,25 1,57 lm LED system solution with outstanding system efficacy up to 113 lm/w, consisting of linear LED module and dimmable LED control gear
FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5
F ballasts T PCA T EXCE oneall lp Y, x1/ W and x1/ W EXCE T Product description Processor-controlled ballast with y inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via
PPL Electric Utilities Energy Efficiency and Conservation Program
Category Measure Qualification Fixtures/Lamps Controls Incentive Amount T-8 Lighting Package Must replace T12. T8 Lamp Fixture $14/fixture (lamp & electronic ballast) High Performance / Replacing T12 $19/fixture
Lumination LED Luminaires
GE Lighting Lumination LED Luminaires Downlights RX Series Dependable Downlighting New GE Lumination RX Downlights are the economical choice for converting existing CFL sockets to the superior performance
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, 14 80 W EXCEL T5
E T5 TC- PCA T5 EXCE oneall lp Y II, 1 80 W EXCE T5 Product description Processor-controlled ballast with y II inside Highest possible energy class CEMA EEI = A1 BAT 1 oise-free precise control via I or
E-CORE Candle 6W. Data Sheet 1 / 5
Data Sheet 1 / 5 E-CORE Candle 6W E-CORE Spherical 6W With its facetted crystal optics, the E-CORE CANDLE is a real head-turner. Smooth dimming, this light is the magic every chandelier needs. The E-CORE
Selection Guide for Conversion of Carbon Composition Resistors
Selection Guide for Conversion of Carbon Composition Resistors believes that the information described in this publication is accurate and reliable, and much care has been taken in its preparation. However,
Quick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
Case Studies in On-Line Measurement of PD in Motors Fed by Voltage Source PWM Drives
Case Studies in On-Line Measurement of PD in Motors Fed by Voltage Source PWM Drives G.C. Stone, I. Culbert, H.G. Sedding Qualitrol-Iris Power Mississauga, Ontario, Canada Abstract On-line partial discharge
Fortimo LED Line Gen3
LED Line 1 ft 1100 lm 1R LV3 Datasheet Fortimo LED Line Gen3 Fortimo LED Line systems are designed to produce pure white light for general lighting applications with high efficiency levels. The Fortimo
Petrol Station Canopies
Petrol Station Canopies High bay & Low Bay Warehouses & Factories Security Lighting General Area Lighting 320W High Bay Ideal for warehouses and factories, the Advantage Hi-Bay offers 20% energy savings
Table of Contents HID Electronic and Electromagnetic Ballasts
Table of Contents HID Electronic and Electromagnetic Ballasts gelighting.com Ballasts Understanding Electronic UltraMax HID Ballasts...18-2 Understanding Electromagnetic HID Ballasts...18-3 Electronic
1SMB59xxBT3G Series, SZ1SMB59xxT3G Series. 3 Watt Plastic Surface Mount Zener Voltage Regulators
9xxBTG Series, SZ9xxTG Series Watt Plastic Surface Mount Zener Voltage Regulators This complete new line of W Zener diodes offers the following advantages. Features Zener Voltage Range. V to V ESD Rating
HANDY INFORMAL LIGHTING GLOSSARY
HANDY INFORMAL LIGHTING GLOSSARY 2 nd Generation T8s Mid-grade 800 series T8s. Typically these F32T8s have 2950 3000 catalog or photopic lumens. 3 rd Generation T8s Also called Super T8s. High-lumen 800
IKEA Light Sources Technical Information Update
Art No. IKEA Light Sources Technical Art Name Update date 10175914 HALOGEN bulb G9 40W clear 2-p 2013-02-13 20152808 HALOGEN bulb E14 28W clear 2-p 2013-02-13 20168381 HALOGEN bulb E14 18W clear 2-p 2013-02-13
Radiance Angle [ ] Nominal Power [W] Color Temp. [K]
PrevaLED COIN 111 Technical Information Benefits Fits in most existing R111 traditinoal luminaires Easy & fast design-in for luminaire manufacturers Narrow beam angles, 24 o and 40 o High lumen output
A Guide to Energy Efficient and Cost Effective Lighting
A Guide to Energy Efficient and Cost Effective Lighting This guide provides information on how specifiers and designers can improve the quality and cost effectiveness of lighting schemes through the use
ARTIFICIAL LIGHTING lecture notes
ARTIFICIAL LIGHTING lecture notes Dr. Habil. András Majoros Figures, images and tables by Levente Filetóth Budapest University of Technology and Economics Faculty of Architecture Department of Building
Product and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
SAMSUNG ELECTRONICS LED
INTRODUCING: SAMSUNG ELECTRONICS LED Lamps Technical data sheet [art 4_2013 2Q] Lighting Marketing Group [EU_Q2 2013]_ Er reparation Light up your Imagination with new LED lighting! A new light with a
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
6 ELECTRICAL PARAMETERS
6 ELECTRICAL PARAMETERS For power, low voltage and medium voltage cables, cross section nominal areas are calculated in taking into account several parameters as: permissible current carrying capacities
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Technical Specification
Application Examples: Suitable for Domestic & Commercial Installations Indoor / Outdoor Use (Suitable Fittings) Typical Installations: Cabinet Lighting Under Cupboard Lighting Wall Lighting Walk Over Lighting
0.9V Boost Driver PR4403 for White LEDs in Solar Lamps
0.9 Boost Driver for White LEDs in Solar Lamps The is a single cell step-up converter for white LEDs operating from a single rechargeable cell of 1.2 supply voltage down to less than 0.9. An adjustable
Pulse Withstanding Thick Film Chip Resistor-SMDP Series. official distributor of
Product: Pulse Withstanding Thick Film Chip Resistor-SMDP Series Size: /// official distributor of Pulse Withstanding Thick Film Chip Resistor-SMDP Series 1. Scope -This specification applies to ~ sizes
Linear Fluorescent Lamp Guide
GE Lighting Linear Fluorescent Lamp Guide The energy efficient choice for every application Linear fluorescent. Efficient and environmentally friendly. Discover the advantages at a glance: Outstanding
UMEC International Corporation
UP1301A SERIES 130 Watt Open Frame Switchers Small Size 3*5*1.2(inches) Universal Input to 264 VAC Low Power Consumption Overvoltage Protection Continuous Short Circuit Protection Over Temperature Protection
STRATO LED Drivers 70W, Single output
Features STRATO switch mode driver technology is designed to generate one constant current output from a wide range AC input. The size and performance of these products make them the ideal choice for LED
Cree XLamp XM-L LED 10,000-Lumen High-Bay Reference Design
application note Cree XLamp XM-L LED 10,000-Lumen High-Bay Reference Design CLD-AP96 rev 0A Table of Contents Introduction... 1 Design approach/objectives... 2 The 6-step methodology... 2 1. Define lighting
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Why Philips LEDtube? LED Lamps EMEA February 2015. February 2015_BG LS & E LEDlamps
Why Philips LEDtube? LED Lamps EMEA February 2015 Content Why Philips? Why LEDtubes? Why Philips LEDtubes? Why Philips? Innovation leader in linear lighting Lighting experience Real quality of light Why
High-ohmic/high-voltage resistors
FEATURES High pulse loading capability Small size. APPLICATIONS Where high resistance, high stability and high reliability at high voltage are required High humidity environment White goods Power supplies.
IPS HIGH-BAY / LOW-BAY LIGHTING
HIGH-BAY / LOW-BAY LIGHTING NEW ALTERNATIVES TO H.I.D. New from SPI LIGHTING, an exciting addition to our family of fluorescent alternatives to traditional HID high-bay and low-bay lighting. The IPS Series
KATO. LED Lighting High Bay und Low Bay
LED Lighting High Bay und Low Bay KATO Very powerful, highly efficient and quickly installed /This is Why KATO is the ideal luminaire for high ceiling rooms and outdoor areas. KATO L (high bay) KATO S
Advanced Monolithic Systems
Advanced Monolithic Systems FEATURES Three Terminal Adjustable or Fixed oltages* 1.5, 1.8, 2.5, 2.85, 3.3 and 5. Output Current of 1A Operates Down to 1 Dropout Line Regulation:.2% Max. Load Regulation:.4%
Nashville Electric Service
Nashville Electric Service Specification ESL-601-1 Description: High Intensity Discharge Lamps 1.0 Scope... 2 2.0 General Requirements... 2 3.0 Information to be Returned... 4 4.0 NES Policy... 4 5.0 Revision
Distributed Array LED Modules High efficacy solutions for diffuse ambient lighting
www.osram-americas.com/led Distributed Array LED Modules High efficacy solutions for diffuse ambient lighting Key Features & Benefits High efficacy Boards incorporate multiple LEDs driven at low-current
Fortimo LED SLM Gen4
Fortimo LED SLM Gen4 Fortimo LED SLM Food L19 The Fortimo LED SLM Gen4 is a next generation solution for spotlight and mini-downlight applications. It is a product in line with the Fortimo brand promise
LIGHTING and LIGHTING SYSTEMS
LIGHTING and LIGHTING SYSTEMS Introduction Lighting is an important area of opportunity for energy savings, since it is a large fraction of use of electricity in residential and commercial buildings. Lighting
Radiance Angle [ ] Color Temp. [K]
PrevaLED COIN 50 Technical Information Benefits Fits in most existing MR16 traditional luminaires Easy & fast design-in for luminaire manufacturers Narrow beam angles, 24 o and 40 o High lumen output for
TISP4500H3BJ Overvoltage Protector
*RoHS COMPLINT TISP4500H3BJ BIDIRECTIONL THYRISTOR OVERVOLTGE PROTECTORS TISP4500H3BJ Overvoltage Protector Non-Conductive During K.20/21/45 Power Contact Test - Off-State Voltage... >245 V rms - For Controlled
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD)
Guidance for upgrading to GB4943.1-2011 (IEC 60950-1: 2005, MOD) Note: This guidance document is a translation of official Chinese document which is issued by CQC (China Quality Certification Center) on
Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch
echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data
SMD version of BUK118-50DL
DESCRIPTION QUICK REFERENCE DT Monolithic temperature and SYMBOL PRMETER MX. UNIT overload protected logic level power MOSFET in TOPFET2 technology V DS Continuous drain source voltage 50 V assembled in
Discontinued. LUXEON V Portable. power light source. Introduction
Preliminary Technical Datasheet DS40 power light source LUXEON V Portable Introduction LUXEON is a revolutionary, energy efficient and ultra compact new light source, combining the lifetime and reliability
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
The new generation of energy saving tube lighting
The new generation of energy saving tube lighting MASTER LEDtube GA The Philips MASTER LEDtube integrates a LED light source into a traditional fluorescent form factor. Its unique design creates a perfectly
ENERGY EFFICIENT LIGHTING
ENERGY EFFICIENT LIGHTING Prof. Suryanarayana y Doolla IIT Bombay Dept. of Energy Science & Engineering Content 2 Basics of Illumination Types of light source, lighting Comparison of commercial lamps Energy
Aluminum Electrolytic Capacitors Power Economic Printed Wiring
Aluminum Electrolytic Capacitors Power Economic Printed Wiring 0/0 PECPW 00/0 PEDPW Fig. QUICK REFERENCE DATA DESCRIPTION high ripple current 0/0 PECPW long life 0 C Nominal case size (Ø D x L in mm) Rated
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
