1 SPUSC 2008 SOUTH PACIFIC USER SERVICES CONFERENCE DATA CENTRE DESIGN AND ENERGY INITIATIVES Presented by Jarrad Clift Electrical Engineer Greenstar Accredited
2 Presentation Content Data Centres General Planning a new Data Centre Capacity Heat Load Space Day 1 and Ultimate t Energy Usage in Data Centres PUE Carbon Emissions Monitoring Facilities Energy Initiatives Co generation and Tri Generation Free air cooling Questions
3 General Data centres are critical to the ongoing reliability and expandability of an organisations Data centres are critical to the ongoing reliability and expandability of an organisations processes and operations.
4 Planning a New Data Centre Capacity Considerations IT Equipment Heat Loads Expansion Forecasting Expandability & Modularity Uninterruptible Power Supply (UPS) Systems Air Conditioning Systems
5 Planning a New Data Centre Capacity Considerations Space Number of Racks Delivery of Cooling Plant Equipment New Concepts Server Virtualisation Techniques Third Party Providers
6 Energy Usage in Data Centres Responsible for around 2.5% of global energy consumption Global demand for data centres continues to increase Energy costs increasing Carbon Trading Scheme
7 Energy Usage in Data Centre Contribution to Energy Usage Typical Data Centre 8% Power System 12% Miscellaneous Losses 36% Cooling 44% IT Equipment
8 Energy Usage in Data Centres Power Usage Effectiveness (PUE) = 1.2 State of the Art = 1.5 Improved Operations = Historical > Poor
9 Energy Usage in Data Centres Cost Analysis Sensitivity of Annual Power Costs to PUE Rating Data Centre IT Equipment Load is 1MW PUE Annual Power Usage Annual Power Bill (at say $0.15/kWh) GWh $180, GWh $225, GWh $300, GWh $375, GWh $450,000.00
10 Energy Usage in Data Centres Cost Analysis Sensitivity of Annual Power Costs to Utility Supply Charges Data Centre IT Equipment Load is 1MW PUE = 2.0 (Average) Electricity Unit Price Annual Power Bill $0.15 kwh $ 300, $0.20 kwh $ 400, $0.25 kwh $ 500, $0.30 kwh $ 600, $0.50 kwh $ 1,000, Energy UsageisImportant!!
11 Energy Usage in Data Centres Carbon Footprint CO 2 Emissions per MWh of Electricity South Australia Approximately 0.98 tonne CO 2 per MWh generated Data Centre Comparison Design 1 IT Equipment Load = 1MW PUE = 1.5 1MW of IT Equipment = 8.76 GWh per Annum Carbon Footprint = 8.76 GWh x 1.5 (PUE) x 0.98 Design 2 IT Equipment Load = 1MW PUE = ,000 Tonnes of CO 2 per Annum 1MW of IT Equipment = 8.76 GWh per Annum Carbon Footprint = 8.76 GWh x 2.0 (PUE) x ,000 Tonnes of CO 2 per Annum
12 Energy Initiatives Co Generation The simultaneous production of electric power and heating from a single fuel source. Efficiencies Gas Fired : 30% Co Generation improves efficiency of power usage Capturing waste heat Widely accepted in the commercial market place Examples; Steam Generation, Hot Water Avoids losses associated with transportation of electricity
13 Energy Initiatives Tri Generation The simultaneous production of electric power, heating and cooling from a single fuel source. Tri Generation Schematic
14 Energy Initiatives Worked Example Computer Room Assumptions IT Equipment Load = 300kWe PUE = 1.5 TtlDt Total Data Centre Load = 450 kwe Electrical Supply Charge = $0.15 kwh Gas Supply Charge = $0.013 MJ Gas Fired Generator Efficiency 30% Air Conditioning Equipment = 300 kwr = 60 kwe (Coeff Perf. = 5) Mains Only Supply = 450 kwe Tri Generation Generation System Installation = 450 kwe 60 kwe (Almost) =390 kwe
15 Energy Initiatives Worked Example Electrical Power Consumed (per Annum) Mains Power Supply Only 450 kw x 8760 = 3.9 GWh Tri Generation System 0 kwh Gas Consumption (per Annum) 0 MJ 3.2 GJ x 8760 = 31,500 GJ Total Cost (PA) $585, $409, Carbon Emissions (PA) 3,822 Tonnes of CO 2 1,575 Tonnes of CO 2 Cost Saving $175, per Annum More than 50% reduction in CO 2 Emissions Capital Cost Capital Cost of Tri Generation Plant Capital Cost Payback Period 7.8 years $3, per kwe = $3, x 390 kwe $1.365 M
16 Energy Initiatives Free Air Cooling The ability to remove heat from a space without the use of the refrigeration process Air Conditioning Units: >50% of energy use if for refrigeration process Adelaide Climate 3,300 hours ( 35% of year) of conditions suitable for free air cooling Direct Free Air Indirect Free Air
17 Energy Initiatives Free Air Cooling Design Example IT Equipment Heat Load = 1 MWe Air Conditioning Equipment Load 330 kwe (Coeff Perf. = 3) Contribution of Refrigeration Process 200 kwe (60%) Availability of Free Air Cooling Operation (Adelaide) Energy Saving = 3,300 hours = 3,300 x 200 kwe = 660,000 kwh per Annum Cost Saving = 660,000 kwh x $0.15 $100,000 per Annum Carbon Emission Reduction = 660 MWh x Tonnes of CO 2 per Annum
18 Summary Correct planning and forecasting for the design requirements of a data centre ensures that the performance requirements are achieved IT and Facility Managers working in a collaborative approach will optimise data centre deliverables Energy efficient design solutions are available Tri Generation and Free Air Cooling Solutions greatly reduce operating costs and energy usage Research, planning and delivery!
University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008
University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008 Contents Welcome and Introduction Chapter 1: Data centre energy recap Chapter 2: Co-generation Chapter 3: CTC case study
Low Carbon Data Centres without compromise
Low Carbon Data Centres without compromise Thursday 16 th September 2010 Pip Squire, Engineering & Project Director delivered by: Ark Continuity - Continuously Delivering high integrity data centres Introduction
Boilers and cogeneration/trigeneration. Abhi Sawant Business Development Manager Simons Green Energy
Boilers and cogeneration/trigeneration Abhi Sawant Business Development Manager Simons Green Energy HEATING - COOLING - SUSTAINABLE ENERGY ENERGY EFFICIENCY IN BOILERS, COGENERATION & TRIGENERATION Presented
Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres
What factors determine the energy efficiency of a data centre? Where is the energy used? Local Climate Data Hall Temperatures Chiller / DX Energy Condenser / Dry Cooler / Cooling Tower Energy Pump Energy
ICT and the Green Data Centre
ICT and the Green Data Centre Scott McConnell Sales Manager c/o Tanya Duncan MD Interxion Ireland Green Data Centres Our Responsibility Data centre greenhouse gas emissions are projected to quadruple by
CHP - The Business Case
CHP - The Business Case An Introduction to Combined Heat and Power CHP 100 1 Acknowledgements 2 Overview! When Does CHP Make Sense! Where is CHP Practical?! Problems in CHP Economic Analysis 3 When Does
ENERGY EFFICIENT DATA CENTRES AND STORAGE. Peter James University of Bradford
ENERGY EFFICIENT DATA CENTRES AND STORAGE Peter James University of Bradford ABOUT US 1998 Co-founded world s first NGO on GreenIT EU Expert Advisors/Project Managers on ICT & Energy Efficiency; Environmental
Energy Efficiency Opportunities Report 2010. Continuing our sustainability journey
Energy Efficiency Opportunities Report 2010 Continuing our sustainability journey Contents Our sustainability journey 2 Commonwealth Bank Place 2 Extending solar photovoltaic expertise to our customers
Sustainable Schools 2009. Renewable Energy Technologies. Andrew Lyle RD Energy Solutions
Sustainable Schools 2009 Renewable Energy Technologies Andrew Lyle RD Energy Solutions RD Energy Solutions Energy efficiency and renewable energy consultancy Project management of installations Maintenance
CRITICAL COOLING FOR DATA CENTERS
IDEA 100 th Annual Conference & Trade Show CRITICAL COOLING FOR DATA CENTERS Presented by Ron Johanning, PE, LEED AP Mission Critical Market Leader Agenda EPA Report Data Center Energy Trends IT Best Practice
Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling
Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling Indirect Adiabatic and Evaporative Data Centre Cooling Solutions by
Recommendations for Measuring and Reporting Overall Data Center Efficiency
Recommendations for Measuring and Reporting Overall Data Center Efficiency Version 2 Measuring PUE for Data Centers 17 May 2011 Table of Contents 1 Introduction... 1 1.1 Purpose Recommendations for Measuring
European Business Reliance Centres when Commodity serves Green IT
European Business Reliance Centres when Commodity serves Green IT www.ebrc.com www.trusteddatacentre.com www.trustedcloudeurope.com www.trustedmanagedservices.com ebrc COMPANY PROFILE 5 datacenters = 17.000
Best Practice Guide BPGCS007
Best Practice Guide BPGCS007 ENERGY MANAGEMENT Introduction: With rising fuel costs, opening of electricity and gas markets to alternate suppliers and climate change, the requirement to monitor and reduce
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint
Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint Energy usage in the data center Electricity Transformer/ UPS Air 10% Movement 12% Cooling 25% Lighting, etc. 3% IT Equipment
World s Greenest High Performance Data Center
World s Greenest High Performance Data Center EcoDataCenter Sustainability for future generations Our Services Colocation Data Center for Mission Critical Requirements Lockable racks, cages, private rooms
Making Existing Server Rooms More Efficient Steve Bowes-Phipps, Data Centre Manager University of Hertfordshire. http://rare-idc.herts.ac.
Making Existing Server Rooms More Efficient Steve Bowes-Phipps, Data Centre Manager University of Hertfordshire http://rare-idc.herts.ac.uk Making Existing Server Rooms More Efficient Reduction and Re-use
Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics
On January 13, 2010, 7x24 Exchange Chairman Robert Cassiliano and Vice President David Schirmacher met in Washington, DC with representatives from the EPA, the DOE and 7 leading industry organizations
Direct Fresh Air Free Cooling of Data Centres
White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The
Recommendations for Measuring and Reporting Overall Data Center Efficiency
Recommendations for Measuring and Reporting Overall Data Center Efficiency Version 1 Measuring PUE at Dedicated Data Centers 15 July 2010 Table of Contents 1 Introduction... 1 1.1 Purpose Recommendations
10 Nuclear Power Reactors Figure 10.1
10 Nuclear Power Reactors Figure 10.1 89 10.1 What is a Nuclear Power Station? The purpose of a power station is to generate electricity safely reliably and economically. Figure 10.1 is the schematic of
COFELY DISTRICT ENERGY DELIVERING LOW CARBON SUSTAINABLE ENERGY SOLUTIONS
COFELY DISTRICT ENERGY DELIVERING LOW CARBON SUSTAINABLE ENERGY SOLUTIONS UK s largest provider of Direct Energy schemes COFELY District Energy is the UK s largest district energy company serving users
Overview of Green Energy Strategies and Techniques for Modern Data Centers
Overview of Green Energy Strategies and Techniques for Modern Data Centers Introduction Data centers ensure the operation of critical business IT equipment including servers, networking and storage devices.
OEH Energy Efficient HVAC for Business Training Course
OEH Energy Efficient HVAC for Business Training Course www.environment.nsw.gov.au/training Presenter: Chris Warris, BCW Carbon and Energy Agenda for Today Overview of OEH Energy Efficiency Training Program
THE EUROPEAN GREEN BUILDING PROGRAMME. Technical Module on Combined Heat and Power
THE EUROPEAN GREEN BUILDING PROGRAMME Technical Module on Combined Heat and Power Contents Foreword...1 1. Introduction...2 2. Inventory of the CHP system...3 3. Assessment of technical energy saving measures...5
Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis
Minimising Data Centre Total Cost of Ownership Through Energy Efficiency Analysis Sophia Flucker CEng MIMechE Ing Dr Robert Tozer MSc MBA PhD CEng MCIBSE MASHRAE Operational Intelligence Ltd. [email protected]
Olympic Park & Stratford Energy Schemes Marketing. Kevin McDonald. District Energy Delivery Models the Concession Approach
Olympic Park & Stratford Energy Schemes Marketing Kevin McDonald District Energy Delivery Models the Concession Approach The largest utility company in the world; Local partnerships and bespoke solutions;
Big Buildings lead to big savings
GE Power & Water Distributed Power Big Buildings lead to big savings GE s combined heat and power solutions for commercial buildings and data centers can reduce your costs and emissions. Saving energy,
UNDERSTANDING ENERGY BILLS & TARRIFS
UNDERSTANDING ENERGY BILLS & TARRIFS as part of the Energy Efficiency Information Grants Program Reading and understanding your energy and gas bills is a good first step to help you to identify where you
1. Data Centre Environment Why focus on Data Centres? Hitachi Eco-Friendly Data Centre Solutions
Hitachi Eco-Friendly Data Centre Solutions Why are efficient data centres a necessity and how can they be delivered 24 th September 2009 1 1. Data Centre Environment Why focus on Data Centres? Why are
Metrics for Data Centre Efficiency
Technology Paper 004 Metrics for Data Centre Efficiency Workspace Technology Limited Technology House, PO BOX 11578, Sutton Coldfield West Midlands B72 1ZB Telephone: 0121 354 4894 Facsimile: 0121 354
Corporate Carbon Neutral Plan
This Carbon Neutral Plan will guide the District of 100 Mile House decision making process in terms of reducing corporate energy consumption and greenhouse gas emissions and in achieving carbon neutrality.
T@W Good Practice Form
T@W Good Practice Form Setting Title: Public-private Partnership Leading to a New CHP Plant Utilising Fibre Sludge and Biomass Country: Location: Sweden Mariestad in West Sweden Region Start date: 1999
I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015
I-STUTE Project - WP2.3 Data Centre Cooling Project Review Meeting 8, Loughborough University, 29 th June 2015 Topics to be considered 1. Progress on project tasks 2. Development of data centre test facility
CHP Strategies and Options / Stored Energy. 2014 ENERGY SYMPOSIUM April8, 2014 Reading Country Club
CHP Strategies and Options / Stored Energy Jim Freihaut, Ph.D. Director, DOE Mid Atlantic CHP Technical Assistance Partnership Director, Indoor Aerosol Laboratory Professor, Architectural Engineering 104
Electric Utilities. Introduction to the module
Introduction to the module The electric utilities module is based on a reporting framework produced by the Institutional Investors Group on Climate Change (IIGCC), Ceres, and the Investor Group on Climate
Energy Update Report Summary 2014
Energy Update Report Summary 2014 City Energy Use Overview 2014 Cost of energy in 2014 for the City of Richmond buildings, lighting, water and wastewater services = $6.1 million dollars or 80.4 GWh (this
Energy Management Strategy
Energy Management Strategy Gloucester s Energy Management Strategy sets out the way for the organisation to measure and manage all the energy and water resources it uses. The main areas it looks at are
As close to perfection. development and production. Modular data center
As close to perfection development and production Modular data center August 2014 What is GreenMDC modular data center? Basically it is the modular design construction which is realized by the principle
Legacy Data Centres Upgrading the cooling capabilities What are the options?
Legacy Data Centres Upgrading the cooling capabilities What are the options? Presentation Structure What is a Legacy Data Centre? What is CRAC cooling? ASHRAE Standards Overview Available Cooling Systems
Half the cost Half the carbon
Half the cost Half the carbon the world s most efficient micro-chp What is BlueGEN? The most efficient small-scale electricity generator BlueGEN uses natural gas from the grid to generate electricity within
Locality Energy Action Group
2012 Locality Energy Action Group Reduce Energy Costs and Lower Energy Consumption whilst cutting Carbon Emissions. Locality Energy Action Group Overview Geoff Berry Touchstone Energy Management Services
Insourcing vs. Outsourcing. Bart Leung Senior Associate, Ehvert Mission Critical
Insourcing vs. Outsourcing Bart Leung Senior Associate, Ehvert Mission Critical 1 Agenda Ehvert Mission Critical Data Centres Then and Now Power & Cooling Considerations Costs Making the Choice 2 History
Top Technology for Industry, Agriculture, Business and Communities
Top Technology for Industry, Agriculture, Business and Communities CHP The Technology with a Potential for Saving Energy Combined Heat and Power (CHP) is a highly efficient technology for the conversion
Growing your greenhouse business faster with gas engines.
Growing your greenhouse business faster with gas engines. Our combined heat and power engines can increase the efficiency and profitability of your greenhouses. Because it s not just your plants that need
Integrating End-User and Grid Focused Batteries and Long-Term Power-to-Gas Storage for Reaching a 100 % Renewable Energy Supply
Integrating End-User and Grid Focused Batteries and Long-Term Power-to-Gas Storage for Reaching a 100 % Renewable Energy Supply M. Hlusiak, Ch. Breyer 7 th International Renewable Energy Storage Conference
How To Understand The Emissions Of Westpac Group
Greenhouse gas emissions and energy Unless otherwise stated, all data reflects a July 1 June 30 reporting year. Westpac Group summary Scope 1 and 2 emissions banking operations 1 Australia (tonnes CO 2
3. Buying non-accredited green power from electricity retailer
ATTACHMENT 1 Understanding Australia s Renewable Energy Market In Australia electricity customers have four options for neutralising the greenhouse emissions associated with their electricity use. These
Applicability of Trigeneration Systems in the Hotel Buildings: The North Cyprus Case
Applicability of Trigeneration Systems in Hotel Buildings: The North Cyprus Case M. OZDENEFE, U. ATIKOL Department of Mechanical Engineering Eastern Mediterranean University Gazimagusa, North Cyprus, Mersin
Imperial College Carbon Management Programme
Imperial College Carbon Management Programme (CMP) Page 1 Contents Foreword from Rector 4 Foreword from the Carbon Trust 5 Management Summary 6 1 Introduction 10 1.1 Carbon Management Programme 10 1.2
The School of Oriental and African Studies Carbon Management Plan
Date: 4 th April 2011 Version number 11 Owner: McKinnell Approval route: Executive Board Approval status: Final Contents Foreword from the Director 3 Foreword from the Carbon Trust 4 Management Summary
Venema Advies Nigeria Limited West Africa Data Center Limited. Datacenter Sustainability
Venema Advies Nigeria Limited West Africa Data Center Limited Datacenter Sustainability Lord of War What if I have AIDS? Don't you worry? You worry too much! Why do you worry about something that can kill
Archant London Environmental Awards
Archant London Environmental Awards Environmental Business of the Year Big Yellow Self Storage PLC Barking Central, Hertford Road, Barking, IG11 8BL Introduction Big Yellow is a local business that has
Metering and Managing University of Sheffield Data Centres. Chris Cartledge Independent Consultant [email protected]
Metering and Managing University of Sheffield Data Centres Chris Cartledge Independent Consultant [email protected] Summary ICT Electricity Use Footprint Data Centre Electricity Use European
Wood Pellets for Power and Heat. Gordon Murray, Executive Director
Wood Pellets for Power and Heat Gordon Murray, Executive Director Bioenergy overview Carbon cycle What are wood pellets and how are they made? Pellets for power Pellets for heat The wood pellet industry
Energy and Carbon Management
Energy and Carbon Management Andrew Gardner General Manager Energy and Carbon Management Severn Trent Water [email protected] 30th March 2010 Agenda Why we are investing in Low Carbon Future
Chorley Climate Change Business Grants Guidance Notes
Chorley Climate Change Business Grants Guidance Notes What is the Chorley Climate Change Business Grants scheme? In 2008, Chorley Council pledged to play a key part in reducing the Carbon Footprint of
CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense
CarbonDecisions The green data centre Why becoming a green data centre makes good business sense Contents What is a green data centre? Why being a green data centre makes good business sense 5 steps to
ELECTRICAL ENERGY REDUCTION IN REFRIGERATION AND AIR CONDITIONING Ken Landymore, Director of Operations, Smartcool Systems Inc.
ELECTRICAL ENERGY REDUCTION IN REFRIGERATION AND AIR CONDITIONING Ken Landymore, Director of Operations, Smartcool Systems Inc. 1. INTRODUCTION In the coming decades, actions to limit greenhouse gas emissions
THE BENEFITS OF PC POWER MANAGEMENT (PPM) SOLUTIONS
THE BENEFITS OF PC POWER MANAGEMENT (PPM) SOLUTIONS PC Power Management Made Simple Updated January 2012 Why Green IT Isn t Enough If You Want to Cut Energy Costs PC Power Management (PPM) Saves Energy
Modular Data Centre. Flexible, scalable high performance modular data centre solutions. Data Centre Solutions...energy efficient by design
Data Centre Solutions...energy efficient by design Modular Data Centre Flexible, scalable high performance modular data centre solutions Creating an effective workspace environment The Modular Data Centre
Your partner of choice for integrated energy solutions
E.ON Connecting Energies Your partner of choice for integrated energy solutions Would you like to reduce your company s energy costs? Do you have ambitious environmental objectives? Are you concerned about
CDP7 and OneReport Comparison
24 27 47 KEY Matches data requested within Related to data requested within Not found in and Comparison # 1.1 2.1 3.1 4.1 5.1 6.1 Regulatory Risk Physical Risk General Risk Regulatory Physical General
The natural ombination
The natural ombination DAIKIN ALTHERMA HYBRID HEAT PUMP 2 A new pportunity in residential heating! There is a growing demand from home owners to replace heating systems, especially replacing of gas boilers,
ENVIRONMENT. Aviation. Property. Marine Services. Trading & Industrial. Beverages
ENVIRONMENT Our ultimate goal, which we first articulated in 2010, is for our operating companies to achieve zero net impact on the environment. We call this goal Net Zero. In, we developed a preliminary
Energy Efficiency Best Practice Guide Data Centre and IT Facilities
2 Energy Efficiency Best Practice Guide Data Centre and IT Facilities Best Practice Guide Pumping Systems Contents Medium-sized data centres energy efficiency 3 1 Introduction 4 2 The business benefits
How To Evaluate Cogeneration
Power topic #7018 Technical information from Cummins Power Generation Inc. Evaluating cogeneration for your facility: A look at the potential energy-efficiency, economic and environmental benefits > White
Sample Scope 3 GHG Inventory Reporting Template
Sample Scope 3 GHG Inventory Reporting Template This sample reporting template illustrates the reporting requirements of the Scope 3 Standard. Companies may use any format to report emissions, provided
Best Practice Guide for Data Centres - a UH Perspective Steve Bowes-Phipps, Data Centres Manager University of Hertfordshire
Best Practice Guide for Data Centres - a UH Perspective Steve Bowes-Phipps, Data Centres Manager University of Hertfordshire http://rare idc.herts.ac.uk Best Practice Guide for Data Centres RARE-IDC Overview
AN ENERGY MANAGEMENT PLAN FOR RED MEAT PROCESSING FACILITIES
Literature Review AN ENERGY MANAGEMENT PLAN FOR RED MEAT PROCESSING FACILITIES Project Code: xxxxx Prepared by: Phuong Tang and Mike Jones Energetics Pty Ltd Date Published: April 2014 Published by: Australian
Off-grid Hybrid Solar: Market Overview, Business Case & Technical Considerations
Off-grid Hybrid Solar: Market Overview, Business Case & Technical Considerations Craig Chambers AECOM Australia Pty Ltd of 420 George Street, Sydney, NSW 2000 Australia Keywords : Solar PV, sustainability,
Environmental Performance Data Calculation Standards
Environal Performance Data Calculation Standards Subject Period: April 1, 2012 March 31, 2013 Scope : Fujitsu and Fujitsu Group (For details, refer to the List of Companies Covered by the Report on Environal
Life Cycle Assessment (LCA) of solar cooling systems
IEA ECES and IEA SHC joint workshop» - Solar Heating and Cooling and Energy Storage«November 8, 2011, University Rosenheim, Germany Life Cycle Assessment (LCA) of solar cooling systems Marco Beccali Dipartimento